Study of heat exchange in a 500 MW energy unit boiler convective steam superheater with combustion of Ekibastuzsk coal
Journal Article
·
· Sov. Power Eng. (Engl. Transl.); (United States)
OSTI ID:5627116
In the transfer of heat by radiation, the actual role of the gas tanks located outside the convective steam superheater (ConSS) is relatively small. This has an indirect relationship to planning of massive boiler units, in which the dimensions of the gas tanks between the heating surfaces in the gas conduits are rather large. In the calculation and planning variants for the P-57 boilers, the resulting radiative current arriving at the edge of the volume occupied by the ConSS is high. As a result, the actual heat absorption of the ConSS was less than planned value.
- OSTI ID:
- 5627116
- Journal Information:
- Sov. Power Eng. (Engl. Transl.); (United States), Vol. 10:4
- Country of Publication:
- United States
- Language:
- English
Similar Records
Temperature conditions of the superheaters of the leading boiler P-57 of a 500 MW power unit
Reliability of operation of spray boiler steam coolers of a 500 MW energy unit
Testing and modernization of the steam superheater of the BKZ-420-140-5 head gas-tight boiler
Journal Article
·
Tue Jan 01 00:00:00 EST 1980
· Sov. Power Eng. (Engl. Transl.); (United States)
·
OSTI ID:5627116
Reliability of operation of spray boiler steam coolers of a 500 MW energy unit
Journal Article
·
Wed Apr 01 00:00:00 EST 1981
· Sov. Power Eng. (Engl. Transl.); (United States)
·
OSTI ID:5627116
Testing and modernization of the steam superheater of the BKZ-420-140-5 head gas-tight boiler
Journal Article
·
Mon Nov 01 00:00:00 EST 1982
· Sov. Power Eng. (Engl. Transl.); (United States)
·
OSTI ID:5627116
+1 more