Title: Inadvertent intracoronary stent extraction 10 months after implantation complicating cutting balloon angioplasty for in-stent restenosis

Journal Article · · Cardiovascular Radiation Medicine

We report the case of an unusual complication for Cutting Balloon Angioplasty (CBA) during treatment for instent restenosis (ISR), which resulted in inadvertent intracoronary stent extraction 10 months after implantation. In this case report, CBA was utilized to treat an ISR lesion in the distal right coronary artery (RCA). Due to difficulty in withdrawing the cutting balloon into the guide after treatment of the lesion, the entire system (guide, cutting balloon, and guidewire) was removed as a unit from the body. Upon examination of the system, the previously placed stent in the distal RCA was attached to the microtomes of the cutting balloon. Although the precise mechanisms for stent extraction in this case remain speculative, the initial stent used in the distal RCA may have been undersized, and this may have played a major role in this complication. Although there is limited data regarding the optimal strategy to treat the site of the inadvertent stent extraction, we opted to re-stent the area with a properly-sized coronary stent. Following the intervention, there was no residual stenosis with TIMI 3 flow through the vessel. The patient remained asymptomatic and a serum troponin drawn 18 hours after the procedure was normal, and he was discharged the next day. The interventionist must be vigilant about this rare but serious complication when applying CBA in the treatment of ISR, particularly when an undersized or underdeployed stent is suspected.

OSTI ID:
20650565
Journal Information:
Cardiovascular Radiation Medicine, Vol. 4, Issue 3; Other Information: DOI: 10.1016/S1522-1865(03)00185-9; PII: S1522186503001859; Copyright (c) 2004 Elsevier Science B.V., Amsterdam, The Netherlands, All rights reserved; Country of input: International Atomic Energy Agency (IAEA); ISSN 1522-1865
Country of Publication:
United States
Language:
English

Similar Records

Improved outcome with novel device for low-pressure PTCA in de novo and in-stent lesions
Journal Article · Sat Mar 01 00:00:00 EST 2003 · Cardiovascular Radiation Medicine · OSTI ID:20650565

Effect of force-induced mechanical stress at the coronary artery bifurcation stenting: Relation to in-stent restenosis
Journal Article · Wed May 28 00:00:00 EDT 2014 · Journal of Applied Physics · OSTI ID:20650565

Safety and efficacy of manual stepping and overlapping of {beta}-emitter for diffuse in-stent restenosis lesions
Journal Article · Fri Mar 01 00:00:00 EST 2002 · Cardiovascular Radiation Medicine · OSTI ID:20650565