Title: Bowtie filters for dedicated breast CT: Analysis of bowtie filter material selection

Journal Article · · Medical Physics
DOI:https://doi.org/10.1118/1.4928476· OSTI ID:1400928

Purpose: For a given bowtie filter design, both the selection of material and the physical design control the energy fluence, and consequently the dose distribution, in the object. Using three previously described bowtie filter designs, the goal of this work is to demonstrate the effect that different materials have on the bowtie filter performance measures. Methods: Three bowtie filter designs that compensate for one or more aspects of the beam‐modifying effects due to the differences in path length in a projection have been designed. The nature of the designs allows for their realization using a variety of materials. The designs were based on a phantom, 14 cm in diameter, composed of 40% fibroglandular and 60% adipose tissue. Bowtie design #1 is based on single material spectral matching and produces nearly uniform spectral shape for radiation incident upon the detector. Bowtie design #2 uses the idea of basis‐material decomposition to produce the same spectral shape and intensity at the detector, using two different materials. With bowtie design #3, it is possible to eliminate the beam hardening effect in the reconstructed image by adjusting the bowtie filter thickness so that the effective attenuation coefficient for every ray is the same. Seven different materials were chosen to represent a range of chemical compositions and densities. After calculation of construction parameters for each bowtie filter design, a bowtie filter was created using each of these materials (assuming reasonable construction parameters were obtained), resulting in a total of 26 bowtie filters modeled analytically and in the penelope Monte Carlo simulation environment. Using the analytical model of each bowtie filter, design profiles were obtained and energy fluence as a function of fan‐angle was calculated. Projection images with and without each bowtie filter design were also generated using penelope and reconstructed using FBP. Parameters such as dose distribution, noise uniformity, and scatter were investigated. Results: Analytical calculations with and without each bowtie filter show that some materials for a given design produce bowtie filters that are too large for implementation in breast CT scanners or too small to accurately manufacture. Results also demonstrate the ability to manipulate the energy fluence distribution (dynamic range) by using different materials, or different combinations of materials, for a given bowtie filter design. This feature is especially advantageous when using photon counting detector technology. Monte Carlo simulation results from penelope show that all studied material choices for bowtie design #2 achieve nearly uniform dose distribution, noise uniformity index less than 5%, and nearly uniform scatter‐to‐primary ratio. These same features can also be obtained using certain materials with bowtie designs #1 and #3. Conclusions: With the three bowtie filter designs used in this work, the selection of material is an important design consideration. An appropriate material choice can improve image quality, dose uniformity, and dynamic range.

Sponsoring Organization:
USDOE
OSTI ID:
1400928
Journal Information:
Medical Physics, Journal Name: Medical Physics Vol. 42 Journal Issue: 9; ISSN 0094-2405
Publisher:
Wiley Blackwell (John Wiley & Sons)Copyright Statement
Country of Publication:
United States
Language:
English
Citation Metrics:
Cited by: 4 works
Citation information provided by
Web of Science

References (30)

A method for comparing beam-hardening filter materials for diagnostic radiology: Comparison of beam-hardening filter materials for diagnostic radiology journal July 1988
Computational Methods for the Design of Test Objects and Tissue Substitutes for Radiologic Applications journal September 1993
Photon counting spectral CT versus conventional CT: comparative evaluation for breast imaging application journal March 2011
Cone-beam volume CT breast imaging: Feasibility study journal April 2002
Bowtie filters for dedicated breast CT: Theory and computational implementation: Bowtie filters for dedicated breast CT journal March 2015
Investigating the effect of characteristic x-rays in cadmium zinc telluride detectors under breast computerized tomography operating conditions journal October 2013
Dosimetric characterization of a dedicated breast computed tomography clinical prototype: Dedicated breast CT dosimetry journal July 2010
Evaluation of x-ray scatter properties in a dedicated cone-beam breast CT scanner: Scatter properties in cone-beam breast CT scanner journal August 2005
Dedicated Breast CT: Initial Clinical Experience journal March 2008
Computed Tomography for Imaging the Breast journal October 2006
Absorbed Radiation Dose in Mammography journal February 1979
Practical cone-beam algorithm journal January 1984
Ultra High Flux 2-D CdZnTe Monolithic Detector Arrays for X-Ray Imaging Applications journal August 2007
Compensators for dose and scatter management in cone-beam computed tomography: Compensators for cone-beam CT journal June 2007
A quality assurance program for image quality of cone-beam CT guidance in radiation therapy: Image quality QA of cone-beam CT journal April 2008
Photon counting spectral breast CT: Effect of adaptive filtration on CT numbers, noise, and contrast to noise ratio: Effect of adaptive filtration in spectral breast CT journal April 2013
Projection x-ray imaging with photon energy weighting: experimental evaluation with a prototype detector journal July 2009
Spectral optimization for dedicated breast CT: Spectral optimization for dedicated breast CT journal December 2010
Effect of shaped filter design on dose and image quality in breast CT journal May 2013
Breast CT journal August 2007
A PENELOPE -based system for the automated Monte Carlo simulation of clinacs and voxelized geometries-application to far-from-axis fields : Automated MC simulation of clinacs with journal October 2011
Characterization of scatter radiation in cone beam CT mammography conference April 2005
Impact of miscentering on patient dose and image noise in x-ray CT imaging: Phantom and clinical studies journal July 2012
The influence of bowtie filtration on cone-beam CT image quality: The influence of bowtie filtration on cone-beam CT image quality journal December 2008
The effects of compensator and imaging geometry on the distribution of x-ray scatter in CBCT: CBCT scatter analysis: Compensator and imaging geometry journal January 2011
Cone-Beam CT for Breast Imaging: Radiation Dose, Breast Coverage, and Image Quality journal August 2010
Photon counting energy dispersive detector arrays for x-ray imaging conference October 2007
Dedicated Breast CT: Radiation Dose and Image Quality Evaluation journal December 2001
Experimentally determined spectral optimization for dedicated breast computed tomography: Experimentally determined spectral optimization for dedicated breast CT journal January 2011
Photon-counting spectral computed tomography using silicon strip detectors: a feasibility study journal March 2010

Similar Records

Bowtie filters for dedicated breast CT: Analysis of bowtie filter material selection
Journal Article · Tue Sep 15 00:00:00 EDT 2015 · Medical Physics · OSTI ID:1400928

Bowtie filters for dedicated breast CT: Theory and computational implementation
Journal Article · Mon Mar 02 00:00:00 EST 2015 · Medical Physics · OSTI ID:1400928

Bowtie filters for dedicated breast CT: Theory and computational implementation
Journal Article · Sun Mar 15 00:00:00 EDT 2015 · Medical Physics · OSTI ID:1400928

Related Subjects