skip to main content
OSTI.GOV title logo U.S. Department of Energy
Office of Scientific and Technical Information

Title: Operating experience of a selective catalytic reduction system for flue gas denitrification in a coal-fired cogeneration plant

Conference ·
OSTI ID:103729
;  [1];  [2];  [3]
  1. Foster Wheeler Energy Corp., Clinton, NJ (United States)
  2. Bechtel Corp., Gaithersburg, MD (United States)
  3. US Generating Co., Carneys Point, NJ (United States)

A pulverized coal-fired cogeneration facility, referred to as the Carneys Point Generating Plant, is the first US coal plant equipped with an ammonia-based selective catalytic reduction (SCR) system. The facility was started up in late 1993 and began supplying electricity to Atlantic Electric Company in early January 1994. Commercial operation officially began in the week of March 13, 1994 and the final acceptance tests were completed successfully in May of 1994. This paper presents the description of the facility and SCR system, followed by the operating experience of the SCR system since its initial startup, including: the NOx reduction performance, ammonia injection system and flow control, and compliance with the regulations and requirements of the State of New Jersey Department of Environmental Protection.

OSTI ID:
103729
Report Number(s):
CONF-950414-; TRN: IM9541%%168
Resource Relation:
Conference: 57. annual American power conference, Chicago, IL (United States), 18-20 Apr 1995; Other Information: PBD: 1995; Related Information: Is Part Of American Power Conference: Proceedings. Volume 57-II; PB: 914 p.
Country of Publication:
United States
Language:
English