Operating Experience Review of the INL HTE Gas Monitoring System
Conference
·
OSTI ID:980799
This paper describes the operations of several types of gas monitors in use at the Idaho National Laboratory (INL) High Temperature Electrolysis Experiment (HTE) laboratory. The gases monitored at hydrogen, carbon monoxide, carbon dioxide, and oxygen. The operating time, calibration, and unwanted alarms are described. The calibration session time durations are described. Some simple statistics are given for the reliability of these monitors and the results are compared to operating experiences of other types of monitors.
- Research Organization:
- Idaho National Lab. (INL), Idaho Falls, ID (United States)
- Sponsoring Organization:
- DOE - NE
- DOE Contract Number:
- DE-AC07-05ID14517
- OSTI ID:
- 980799
- Report Number(s):
- INL/CON-09-17441; TRN: US201012%%928
- Resource Relation:
- Conference: Second International Meeting of the Safety and Technology of Nuclear Hydrogen Production, Control an,San Diego, CA,06/13/2010,06/17/2010
- Country of Publication:
- United States
- Language:
- English
Similar Records
Operating experience review of an INL gas monitoring system
Hydrogen and Oxygen Gas Monitoring System Design and Operation
Integrated Operation of INL HYTEST System and High-Temperature Steam Electrolysis for Synthetic Natural Gas Production
Journal Article
·
Thu Mar 12 00:00:00 EDT 2015
· Journal of Chemical Health and Safety
·
OSTI ID:980799
Hydrogen and Oxygen Gas Monitoring System Design and Operation
Conference
·
Fri Jun 01 00:00:00 EDT 2007
·
OSTI ID:980799
Integrated Operation of INL HYTEST System and High-Temperature Steam Electrolysis for Synthetic Natural Gas Production
Conference
·
Tue Jun 01 00:00:00 EDT 2010
·
OSTI ID:980799