Title: Temperature effects on sealed lead acid batteries and charging techniques to prolong cycle life.

Technical Report ·
DOI:https://doi.org/10.2172/975252· OSTI ID:975252

Sealed lead acid cells are used in many projects in Sandia National Laboratories Department 2660 Telemetry and Instrumentation systems. The importance of these cells in battery packs for powering electronics to remotely conduct tests is significant. Since many tests are carried out in flight or launched, temperature is a major factor. It is also important that the battery packs are properly charged so that the test is completed before the pack cannot supply sufficient power. Department 2665 conducted research and studies to determine the effects of temperature on cycle time as well as charging techniques to maximize cycle life and cycle times on sealed lead acid cells. The studies proved that both temperature and charging techniques are very important for battery life to support successful field testing and expensive flight and launched tests. This report demonstrates the effects of temperature on cycle time for SLA cells as well as proper charging techniques to get the most life and cycle time out of SLA cells in battery packs.

Research Organization:
Sandia National Laboratories (SNL), Albuquerque, NM, and Livermore, CA (United States)
Sponsoring Organization:
USDOE
DOE Contract Number:
AC04-94AL85000
OSTI ID:
975252
Report Number(s):
SAND2004-3149; TRN: US201009%%445
Country of Publication:
United States
Language:
English

Similar Records

Testing of sealed lead-acid batteries. Revision
Technical Report · Wed May 01 00:00:00 EDT 1985 · OSTI ID:975252

Sealed lead-acid batteries for solar applications
Conference · Sun Jan 01 00:00:00 EST 1984 · OSTI ID:975252

Sealed lead-acid batteries for solar applications
Journal Article · Mon Oct 01 00:00:00 EDT 1984 · Proc. - Electrochem. Soc.; (United States) · OSTI ID:975252