skip to main content
OSTI.GOV title logo U.S. Department of Energy
Office of Scientific and Technical Information

Title: ISOTOPIC COMPOSITIONS OF URANIUM REFERENCE MATERIALS

Conference ·
OSTI ID:969822

Uranium isotopic compositions of a variety of U standard materials were measured at Lawrence Livermore National Laboratory and are reported here. Both thermal ionization mass spectrometry (TIMS) and multi-collector inductively couple plasma mass spectrometry (MC-ICPMS) were used to determine ratios of the naturally occurring isotopes of U. Establishing an internally coherent set of isotopic values for a range of U standards is essential for inter-laboratory comparison of small differences in {sup 238}U/{sup 235}U, as well as the minor isotopes of U. Differences of {approx} 1.3{per_thousand} are now being observed in {sup 238}U/{sup 235}U in natural samples, and may play an important role in understanding U geochemistry where tracing the origin of U is aided by U isotopic compositions. The {sup 238}U/{sup 235}U ratios were measured with a TRITON TIMS using a mixed {sup 233}U-{sup 236}U isotopic tracer to correct for instrument fractionation. this tracer was extremely pure and resulted in only very minor corrections on the measured {sup 238}U/{sup 235}U ratios of {approx} 0.03. The values obtained for {sup 238}U/{sup 235}U are: IRMM184 = 137.698 {+-} 0.020 (n = 15), SRM950a = 137.870 {+-} 0.018 (n = 8), and CRM112a = 137.866 {+-} 0.030 (n = 16). Uncertainties represent 2 s.d. of the population. The measured value for IRMM184 is in near-perfect agreement with the certified value of 137.697 {+-} 0.042. However, the U isotopic compositions of SRM950a and CRM112a are not certified. Minor isotopes of U were determined with a Nu Plasma HR MC-ICPMS and mass bias was corrected by sample/standard bracketing to IRMM184, using its certified {sup 238}U/{sup 235}U ratio. Thus, the isotopic compositions determined using both instruments are compatible. The values obtained for {sup 234}U/{sup 235}U are: SRM950a = (7.437 {+-} 0.043) x 10{sup -3} (n = 18), and CRM112a = (7.281 {+-} 0.050) x 10{sup -3} (n = 16), both of which are in good agreement with published values. The value for {sup 236}U/{sup 235}U in SRM950a was determined to be (8.48 {+-} 2.63) x 10{sup -6}, whereas {sup 236}U was not detected in CRM112a. They are currently obtaining the U isotopic composition of CRM129a. Preliminary results suggest that the {sup 238}U/{sup 235}U ratio is within error, but slightly lower than the certified value of 137.71.

Research Organization:
Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States)
Sponsoring Organization:
USDOE
DOE Contract Number:
W-7405-ENG-48
OSTI ID:
969822
Report Number(s):
LLNL-PROC-416585; TRN: US201002%%806
Resource Relation:
Conference: Presented at: American Geophysical Union Fall Meeting 2009, San Francisco, CA, United States, Dec 14 - Dec 18, 2009
Country of Publication:
United States
Language:
English

Similar Records

Certification of Uranium Isotope Amount Ratios in a Suite of Uranium Ore Concentrate Certified Reference Materials
Journal Article · Sun Nov 07 00:00:00 EDT 2021 · Geostandards and Geoanalytical Research · OSTI ID:969822

Investigating Uranium Isotopic Distributions in Environmental Samples Using AMS and MC-ICPMS
Journal Article · Fri Dec 09 00:00:00 EST 2005 · Nuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms · OSTI ID:969822

Semiannual Progress Report for the Period July 1960 through December 1960
Technical Report · Tue Aug 01 00:00:00 EDT 1961 · OSTI ID:969822