skip to main content
OSTI.GOV title logo U.S. Department of Energy
Office of Scientific and Technical Information

Title: Testing of vacuum system for APT/LEDA RFQ

Conference ·
OSTI ID:9621

The authors have designed, built and operated two vacuum systems for the RFQ (Radio Frequency Quadrupole) in the APT/LEDA (Accelerator Production of Tritium/Low Energy Demonstration Accelerator)linac: a cryopump system for the RFQ cavity and a non-evaporable getter (NEG) pump system for the RF window system. They were designed to provide very high hydrogen pump speed (> 2 x 10{sup 4} L/s) and sorption capacity. Both systems underwent performance tests in mock assembly before the installation. This paper presents the mock test results of both vacuum systems. It also discusses the preliminary test results from the commissioning of the APT/LEDA RFQ.

Research Organization:
Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States)
Sponsoring Organization:
USDOE Office of Defense Programs (DP) (US)
DOE Contract Number:
W-7405-ENG-48
OSTI ID:
9621
Report Number(s):
UCRL-JC-133057; DP0404012; DP0404012; TRN: US0103170
Resource Relation:
Conference: Particle Accelerator Conference 1999, New York, NY (US), 03/27/1999--04/04/1999; Other Information: PBD: 25 Mar 1999
Country of Publication:
United States
Language:
English