Stack Monitor Operating Experience Review
Stack monitors are used to sense radioactive particulates and gases in effluent air being vented from rooms of nuclear facilities. These monitors record the levels and types of effluents to the environment. This paper presents the results of a stack monitor operating experience review of the U.S. Department of Energy (DOE) Occurrence Reporting and Processing System (ORPS) database records from the past 18 years. Regulations regarding these monitors are briefly described. Operating experiences reported by the U.S. DOE and in engineering literature sources were reviewed to determine the strengths and weaknesses of these monitors. Electrical faults, radiation instrumentation faults, and human errors are the three leading causes of failures. A representative “all modes” failure rate is 1E-04/hr. Repair time estimates vary from an average repair time of 17.5 hours (with spare parts on hand) to 160 hours (without spare parts on hand). These data should support the use of stack monitors in any nuclear facility, including the National Ignition Facility and the international ITER project.
- Research Organization:
- Idaho National Lab. (INL), Idaho Falls, ID (United States)
- Sponsoring Organization:
- DOE - SC
- DOE Contract Number:
- DE-AC07-99ID-13727
- OSTI ID:
- 957525
- Report Number(s):
- INL/CON-09-15233; TRN: US1000623
- Resource Relation:
- Conference: 23rd Symposium on Fusion Engineering,San Diego, California,05/31/2009,06/05/2009
- Country of Publication:
- United States
- Language:
- English
Similar Records
Reliability Estimates for Power Supplies
Operating Experience Review of Tritium-in-Water Monitors