Title: Buoyancy-Driven Ventilation of Hydrogen from Buildings: Laboratory Test and Model Validation

Abstract

Passive, buoyancy-driven ventilation is one approach to limiting hydrogen concentration. We explored the relationship between leak rate, ventilation design, and hydrogen concentrations.

Authors:
;
Publication Date:
Research Org.:
National Renewable Energy Lab. (NREL), Golden, CO (United States)
Sponsoring Org.:
USDOE
OSTI Identifier:
956886
Report Number(s):
NREL/TP-550-45804
TRN: US201014%%1698
DOE Contract Number:  
AC36-99-GO10337
Resource Type:
Technical Report
Country of Publication:
United States
Language:
English
Subject:
08 HYDROGEN; DESIGN; HYDROGEN; VALIDATION; VENTILATION; BUILDINGS; BUOYANCY; CFD; COMPUTATIONAL FLUID DYNAMICS; Buildings

Citation Formats

Barley, C D, and Gawlik, K. Buoyancy-Driven Ventilation of Hydrogen from Buildings: Laboratory Test and Model Validation. United States: N. p., 2009. Web. doi:10.2172/956886.
Barley, C D, & Gawlik, K. Buoyancy-Driven Ventilation of Hydrogen from Buildings: Laboratory Test and Model Validation. United States. https://doi.org/10.2172/956886
Barley, C D, and Gawlik, K. 2009. "Buoyancy-Driven Ventilation of Hydrogen from Buildings: Laboratory Test and Model Validation". United States. https://doi.org/10.2172/956886. https://www.osti.gov/servlets/purl/956886.
@article{osti_956886,
title = {Buoyancy-Driven Ventilation of Hydrogen from Buildings: Laboratory Test and Model Validation},
author = {Barley, C D and Gawlik, K},
abstractNote = {Passive, buoyancy-driven ventilation is one approach to limiting hydrogen concentration. We explored the relationship between leak rate, ventilation design, and hydrogen concentrations.},
doi = {10.2172/956886},
url = {https://www.osti.gov/biblio/956886}, journal = {},
number = ,
volume = ,
place = {United States},
year = {Fri May 01 00:00:00 EDT 2009},
month = {Fri May 01 00:00:00 EDT 2009}
}