Proposed FNAL 750 KeV Linac Injector Upgrade
Abstract
The present FNAL linac H{sup -} injector has been operational since 1978 and consists of a magnetron H{sup -} source and a 750 keV Cockcroft-Walton Accelerator. The proposed upgrade to this injector is to replace the present magnetron source having a rectangular aperture with a circular aperture, and to replace the Cockcroft-Walton with a 200 MHz RFQ. Operational experience at other laboratories has shown that the upgraded source and RFQ will be more reliable and require less manpower than the present system.
- Authors:
- Publication Date:
- Research Org.:
- Fermi National Accelerator Lab. (FNAL), Batavia, IL (United States)
- Sponsoring Org.:
- USDOE
- OSTI Identifier:
- 952270
- Report Number(s):
- FERMILAB-CONF-09-138-AD
TRN: US0902461
- DOE Contract Number:
- AC02-07CH11359
- Resource Type:
- Conference
- Resource Relation:
- Conference: Presented at Particle Accelerator Conference (PAC 09), Vancouver, BC, Canada, 4-8 May 2009
- Country of Publication:
- United States
- Language:
- English
- Subject:
- 43 PARTICLE ACCELERATORS; ACCELERATORS; APERTURES; COCKCROFT-WALTON ACCELERATORS; LINEAR ACCELERATORS; MAGNETRONS; MANPOWER; Accelerators
Citation Formats
Tan, C Y, Bollinger, D S, Schmidt, C W, and /Fermilab. Proposed FNAL 750 KeV Linac Injector Upgrade. United States: N. p., 2009.
Web.
Tan, C Y, Bollinger, D S, Schmidt, C W, & /Fermilab. Proposed FNAL 750 KeV Linac Injector Upgrade. United States.
Tan, C Y, Bollinger, D S, Schmidt, C W, and /Fermilab. 2009.
"Proposed FNAL 750 KeV Linac Injector Upgrade". United States. https://www.osti.gov/servlets/purl/952270.
@article{osti_952270,
title = {Proposed FNAL 750 KeV Linac Injector Upgrade},
author = {Tan, C Y and Bollinger, D S and Schmidt, C W and /Fermilab},
abstractNote = {The present FNAL linac H{sup -} injector has been operational since 1978 and consists of a magnetron H{sup -} source and a 750 keV Cockcroft-Walton Accelerator. The proposed upgrade to this injector is to replace the present magnetron source having a rectangular aperture with a circular aperture, and to replace the Cockcroft-Walton with a 200 MHz RFQ. Operational experience at other laboratories has shown that the upgraded source and RFQ will be more reliable and require less manpower than the present system.},
doi = {},
url = {https://www.osti.gov/biblio/952270},
journal = {},
number = ,
volume = ,
place = {United States},
year = {Wed Apr 01 00:00:00 EDT 2009},
month = {Wed Apr 01 00:00:00 EDT 2009}
}
Other availability
Please see Document Availability for additional information on obtaining the full-text document. Library patrons may search WorldCat to identify libraries that hold this conference proceeding.
Save to My Library