Abstract

The present FNAL linac H{sup -} injector has been operational since 1978 and consists of a magnetron H{sup -} source and a 750 keV Cockcroft-Walton Accelerator. The proposed upgrade to this injector is to replace the present magnetron source having a rectangular aperture with a circular aperture, and to replace the Cockcroft-Walton with a 200 MHz RFQ. Operational experience at other laboratories has shown that the upgraded source and RFQ will be more reliable and require less manpower than the present system.

Authors:
; ;
Publication Date:
Research Org.:
Fermi National Accelerator Lab. (FNAL), Batavia, IL (United States)
Sponsoring Org.:
USDOE
OSTI Identifier:
952270
Report Number(s):
FERMILAB-CONF-09-138-AD
TRN: US0902461
DOE Contract Number:  
AC02-07CH11359
Resource Type:
Conference
Resource Relation:
Conference: Presented at Particle Accelerator Conference (PAC 09), Vancouver, BC, Canada, 4-8 May 2009
Country of Publication:
United States
Language:
English
Subject:
43 PARTICLE ACCELERATORS; ACCELERATORS; APERTURES; COCKCROFT-WALTON ACCELERATORS; LINEAR ACCELERATORS; MAGNETRONS; MANPOWER; Accelerators

Citation Formats

Tan, C Y, Bollinger, D S, Schmidt, C W, and /Fermilab. Proposed FNAL 750 KeV Linac Injector Upgrade. United States: N. p., 2009. Web.
Tan, C Y, Bollinger, D S, Schmidt, C W, & /Fermilab. Proposed FNAL 750 KeV Linac Injector Upgrade. United States.
Tan, C Y, Bollinger, D S, Schmidt, C W, and /Fermilab. 2009. "Proposed FNAL 750 KeV Linac Injector Upgrade". United States. https://www.osti.gov/servlets/purl/952270.
@article{osti_952270,
title = {Proposed FNAL 750 KeV Linac Injector Upgrade},
author = {Tan, C Y and Bollinger, D S and Schmidt, C W and /Fermilab},
abstractNote = {The present FNAL linac H{sup -} injector has been operational since 1978 and consists of a magnetron H{sup -} source and a 750 keV Cockcroft-Walton Accelerator. The proposed upgrade to this injector is to replace the present magnetron source having a rectangular aperture with a circular aperture, and to replace the Cockcroft-Walton with a 200 MHz RFQ. Operational experience at other laboratories has shown that the upgraded source and RFQ will be more reliable and require less manpower than the present system.},
doi = {},
url = {https://www.osti.gov/biblio/952270}, journal = {},
number = ,
volume = ,
place = {United States},
year = {Wed Apr 01 00:00:00 EDT 2009},
month = {Wed Apr 01 00:00:00 EDT 2009}
}

Conference:
Other availability
Please see Document Availability for additional information on obtaining the full-text document. Library patrons may search WorldCat to identify libraries that hold this conference proceeding.

Save / Share: