Emittance Reduction between EBIS LINAC and Booster by Electron Beam Cooling; Is Single Pass Cooling Possible?
Electron beam cooling is examined as an option to reduce momentum of gold ions exiting the EBIS LINAC before injection into the booster. Electron beam parameters are based on experimental data (obtained at BNL) of electron beams extracted from a plasma cathode. Preliminary calculations indicate that single pass cooling is feasible; momentum spread can be reduced by more than an order of magnitude in less than one meter.
- Research Organization:
- Brookhaven National Lab. (BNL), Upton, NY (United States)
- Sponsoring Organization:
- Doe - Office Of Science
- DOE Contract Number:
- DE-AC02-98CH10886
- OSTI ID:
- 939971
- Report Number(s):
- BNL-81584-2008-IR; R&D Project: 18033; KB0202011; TRN: US0807091
- Country of Publication:
- United States
- Language:
- English
Similar Records
Single pass electron beam cooling of gold ions between EBIS LINAC and booster is theoretically possible!
Part II/Addendum Electron Beam Cooling between EBIS LINAC and Booster; Is Single Pass Cooling Possible?
Issues concerning high current lower energy electron beams required for ion cooling between EBIS LINAC and booster
Technical Report
·
Sat Jan 01 00:00:00 EST 2011
·
OSTI ID:939971
Part II/Addendum Electron Beam Cooling between EBIS LINAC and Booster; Is Single Pass Cooling Possible?
Technical Report
·
Tue Jul 01 00:00:00 EDT 2008
·
OSTI ID:939971
Issues concerning high current lower energy electron beams required for ion cooling between EBIS LINAC and booster
Technical Report
·
Sun Mar 01 00:00:00 EST 2009
·
OSTI ID:939971