Title: SYSTEMATIC ERROR REDUCTION: NON-TILTED REFERENCE BEAM METHOD FOR LONG TRACE PROFILER.

Conference ·
OSTI ID:918596

Systematic error in the Long Trace Profiler (LTP) has become the major error source as measurement accuracy enters the nanoradian and nanometer regime. Great efforts have been made to reduce the systematic error at a number of synchrotron radiation laboratories around the world. Generally, the LTP reference beam has to be tilted away from the optical axis in order to avoid fringe overlap between the sample and reference beams. However, a tilted reference beam will result in considerable systematic error due to optical system imperfections, which is difficult to correct. Six methods of implementing a non-tilted reference beam in the LTP are introduced: (1) application of an external precision angle device to measure and remove slide pitch error without a reference beam, (2) independent slide pitch test by use of not tilted reference beam, (3) non-tilted reference test combined with tilted sample, (4) penta-prism scanning mode without a reference beam correction, (5) non-tilted reference using a second optical head, and (6) alternate switching of data acquisition between the sample and reference beams. With a non-tilted reference method, the measurement accuracy can be improved significantly. Some measurement results are presented. Systematic error in the sample beam arm is not addressed in this paper and should be treated separately.

Research Organization:
Brookhaven National Lab. (BNL), Upton, NY (United States)
Sponsoring Organization:
Doe - Office Of Science
DOE Contract Number:
DE-AC02-98CH10886
OSTI ID:
918596
Report Number(s):
BNL-79345-2007-CP; R&D Project: 07032; KA-04-04; TRN: US0805857
Resource Relation:
Conference: SPIE CONFERENCE; SAN DIEGO, CA; 20070825 through 20070831
Country of Publication:
United States
Language:
English

Similar Records

MULTIPLE FUNCTIONS LONG TRACE PROFILER (LTP-MF) FOR NATIONAL SYNCHROTRON RADIATION LABORATORY OF CHINA.
Conference · Sun Jul 31 00:00:00 EDT 2005 · OSTI ID:918596

Raytracing the long trace profiler
Conference · Fri Aug 21 00:00:00 EDT 2020 · Advances in Metrology for X-Ray and EUV Optics IX · OSTI ID:918596

The penta-prism LTP: A long-trace-profiler with stationary optical head and moving penta prism (abstract)
Journal Article · Wed Feb 01 00:00:00 EST 1995 · Review of Scientific Instruments; (United States) · OSTI ID:918596