skip to main content
OSTI.GOV title logo U.S. Department of Energy
Office of Scientific and Technical Information

Title: ELECTRON COOLING IN THE RECYCLER COOLER

Conference ·
OSTI ID:918593

A 0.1-0.5 A, 4.3 MeV DC electron beam provides cooling of 8 GeV antiprotons in Fermilab's Recycler storage ring. The most detailed information about the cooling properties of the electron beam comes from drag rate measurements. We find that the measured drag rate can significantly differ from the cooling force experienced by a single antiproton because the area of effective cooling is significantly smaller than the physical size of the electron beam and is comparable with the size of the antiproton beam used as a probe. Modeling by the BETACOOL code supports the conclusion about a large radial gradient of transverse velocities in the presently used electron beam.

Research Organization:
Brookhaven National Lab. (BNL), Upton, NY (United States)
Sponsoring Organization:
Doe - Office Of Science
DOE Contract Number:
DE-AC02-98CH10886
OSTI ID:
918593
Report Number(s):
BNL-78080-2007-CP; R&D Project: 18011; KB0202011; TRN: US0805854
Resource Relation:
Conference: COOL 07 - WORKSHOP ON BEAM COOLING AND RELATED TOPICS; BAD KREUZNACH, GERMANY; 20070910 through 20070914
Country of Publication:
United States
Language:
English