Simultaneous determination of Hugoniot and Isentrope in gas gun experiments
We have been exploring the use of the ''reverse ballistics'' method to obtain Hugoniot and off Hugoniot Equation Of State. This method uses the unknown sample as the flyer and collides it into a window whose EOS is well known. A VISAR determines the particle velocity which when combined with the windows EOS gives a direct determination of the pressure. Since the pressure and particle velocity are continuous across the interface the shock speed in the flyer can be determined: Us = P/(rhoUp). Subtracting the time of arrival of the shock at the back of the flyer from the times of arrival of the rarefaction wave allows the determination of the release isentrope centered at the measured Hugoniot point and extending down to the release pressure as determined by the impedance of the sabot. Besides obtaining both Hugoniot and isentrope data on a single shot, this method has an advantage in that all the timing information is accomplished within the interferometer, i.e. no dependence of cable delays etc.
- Research Organization:
- Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States)
- Sponsoring Organization:
- USDOE
- DOE Contract Number:
- W-7405-ENG-48
- OSTI ID:
- 913543
- Report Number(s):
- UCRL-CONF-228393; TRN: US0800766
- Resource Relation:
- Conference: Presented at: 2007 APS SCCM Hawaii, Kona, HI, United States, Jun 24 - Jun 29, 2007
- Country of Publication:
- United States
- Language:
- English
Similar Records
Measurement and analysis of release isentropes using proton radiography (u)
Effect of shear strength on Hugoniot-compression curve and the equation of state of tungsten (W)