Final report on the project entitled: Highly Preheated Combustion Air System with/without Oxygen Enrichment for Metal Processing Furnaces
Abstract
This work develops and demonstrates a laboratory-scale high temperature natural gas furnace that can operate with/without oxygen enrichment to significantly improve energy efficiency and reduce emissions. The laboratory-scale is 5ft in diameter & 8ft tall. This furnace was constructed and tested. This report demonstrates the efficiency and pollutant prevention capabilities of this test furnace. The project also developed optical detection technology to control the furnace output.
- Authors:
- Publication Date:
- Research Org.:
- State of Michigan/The University of Michigan PI-Arvind Atreya
- Sponsoring Org.:
- USDOE Office of Industrial Technologies (OIT) - (EE-20)
- OSTI Identifier:
- 899515
- Report Number(s):
- Final Project Report
TRN: US200711%%589
- DOE Contract Number:
- FC36-02ID14348
- Resource Type:
- Technical Report
- Country of Publication:
- United States
- Language:
- English
- Subject:
- 03 NATURAL GAS; 54 ENVIRONMENTAL SCIENCES; 42 ENGINEERING; AIR; COMBUSTION; DETECTION; EFFICIENCY; ENERGY EFFICIENCY; FURNACES; NATURAL GAS; OXYGEN ENRICHMENT; POLLUTANTS; PROCESSING; Furnaces, Metal processing, Combustion, Homogeneous, Radiation,
Citation Formats
Atreya, Arvind. Final report on the project entitled: Highly Preheated Combustion Air System with/without Oxygen Enrichment for Metal Processing Furnaces. United States: N. p., 2007.
Web. doi:10.2172/899515.
Atreya, Arvind. Final report on the project entitled: Highly Preheated Combustion Air System with/without Oxygen Enrichment for Metal Processing Furnaces. United States. https://doi.org/10.2172/899515
Atreya, Arvind. 2007.
"Final report on the project entitled: Highly Preheated Combustion Air System with/without Oxygen Enrichment for Metal Processing Furnaces". United States. https://doi.org/10.2172/899515. https://www.osti.gov/servlets/purl/899515.
@article{osti_899515,
title = {Final report on the project entitled: Highly Preheated Combustion Air System with/without Oxygen Enrichment for Metal Processing Furnaces},
author = {Atreya, Arvind},
abstractNote = {This work develops and demonstrates a laboratory-scale high temperature natural gas furnace that can operate with/without oxygen enrichment to significantly improve energy efficiency and reduce emissions. The laboratory-scale is 5ft in diameter & 8ft tall. This furnace was constructed and tested. This report demonstrates the efficiency and pollutant prevention capabilities of this test furnace. The project also developed optical detection technology to control the furnace output.},