Title: RIP Input Tables from WAPDEG for LA Design Selection: Enhabced Design Alternatie IV

Abstract

The purpose of this calculation is to document (1) the Waste Package Degradation (WAPDEG) version 3.09 (CRWMS M&O 1998b. ''Software Routine Report for WAPDEG'' (Version 3.09)) simulations used to analyze degradation and failure of 2-cm thick titanium grade 7 corrosion resistant material (CRM) drip shields (that are placed over single-layer waste packages composed of a 30-cm thick A-5 16 carbon steel corrosion allowance material (CAM)) as well as degradation and failure of the waste packages themselves, and (2) post-processing of these results into tables of drip shield/waste package degradation time histories suitable for use as input into the Integrated Probabilistic Simulator for Environmental Systems (RIP) version 5.19.01 (Golder Associates 1998) computer code. This calculation supports Performance Assessment analysis of the License Application Design Selection (LADS) Enhanced Design Alternative IV.

Authors:
Publication Date:
Research Org.:
Yucca Mountain Project, Las Vegas, NV (United States)
Sponsoring Org.:
USDOE
OSTI Identifier:
894186
Report Number(s):
B00000000-01717-0210-00072, Rev. 00
MOL.19990201.0089, DC# 21987; TRN: US200701%%322
DOE Contract Number:  
NA
Resource Type:
Technical Report
Country of Publication:
United States
Language:
English
Subject:
36 MATERIALS SCIENCE; CARBON STEELS; COMPUTER CODES; CORROSION; DESIGN; LICENSE APPLICATIONS; PERFORMANCE; SHIELDS; SIMULATORS; TITANIUM; WASTES

Citation Formats

Mon, K G. RIP Input Tables from WAPDEG for LA Design Selection: Enhabced Design Alternatie IV. United States: N. p., 1999. Web. doi:10.2172/894186.
Mon, K G. RIP Input Tables from WAPDEG for LA Design Selection: Enhabced Design Alternatie IV. United States. https://doi.org/10.2172/894186
Mon, K G. 1999. "RIP Input Tables from WAPDEG for LA Design Selection: Enhabced Design Alternatie IV". United States. https://doi.org/10.2172/894186. https://www.osti.gov/servlets/purl/894186.
@article{osti_894186,
title = {RIP Input Tables from WAPDEG for LA Design Selection: Enhabced Design Alternatie IV},
author = {Mon, K G},
abstractNote = {The purpose of this calculation is to document (1) the Waste Package Degradation (WAPDEG) version 3.09 (CRWMS M&O 1998b. ''Software Routine Report for WAPDEG'' (Version 3.09)) simulations used to analyze degradation and failure of 2-cm thick titanium grade 7 corrosion resistant material (CRM) drip shields (that are placed over single-layer waste packages composed of a 30-cm thick A-5 16 carbon steel corrosion allowance material (CAM)) as well as degradation and failure of the waste packages themselves, and (2) post-processing of these results into tables of drip shield/waste package degradation time histories suitable for use as input into the Integrated Probabilistic Simulator for Environmental Systems (RIP) version 5.19.01 (Golder Associates 1998) computer code. This calculation supports Performance Assessment analysis of the License Application Design Selection (LADS) Enhanced Design Alternative IV.},
doi = {10.2172/894186},
url = {https://www.osti.gov/biblio/894186}, journal = {},