Title: Beam Position Monitoring using the HOM-Signals from a Damped and Detuned Accelerating Structure

Conference ·
OSTI ID:890821

The Next and Global Linear Collider (NLC/GLC) designs require precision alignment of the beam in the accelerator structures to reduce short range wakefields. The moderately damped and detuned structures themselves provide suitable higher order mode (HOM) signals to measure this alignment. The modes in the lowest dipole band, whose frequencies range from 14-16 GHz, provide the strongest signals. To determine the position resolution they provide, an NLC/GLC prototype structure that was installed in the ASSET facility of the SLAC Linac was instrumented to downmix and digitize these signals. The beam position within the structure was determined by simultaneously measuring the signals at three frequencies (14.3, 15, 15.7 GHz) corresponding to modes localized at the beginning, the middle and the end of the 60 cm long structure. A resolution of 1 micron was achieved even with 28 dB signal attenuation, which is better than the 5 micron resolution required for the NLC/GLC.