Title: Calculation of Minimum-Detectable-Concentration Levels of Radioxenon Isotopes Using the PNNL ARSA System

Technical Report ·
DOI:https://doi.org/10.2172/888707· OSTI ID:888707

Measurement of xenon fission product isotopes is a key element in the global network being established to monitor the Comprehensive Nuclear-Test-Ban Treaty. The automated Radio-xenon Analyzer/Sampler (ARSA), built by Pacific Northwest National Laboratory, can detect 131mXe, 133mXe, 133Xe, and 135Xe via a beta-gamma counting system. Due to the variable background and sources of these four radio-xenon isotopes, it is important to have as sensitive a detection system as possible and to quantify the Minimum-Detectable-Concentrations (MDC) that such a system will be able to detect to preclude false negative and false positive results. From data obtained from IAR in Germany MDC values for 133Xe were well below the 1 mBq/SCMA as required by the PTS for the Comprehensive Test BAn Treaty [WGB TL-11,1999].

Research Organization:
Pacific Northwest National Lab. (PNNL), Richland, WA (United States)
Sponsoring Organization:
USDOE
DOE Contract Number:
AC05-76RL01830
OSTI ID:
888707
Report Number(s):
PNNL-13102; NN2003000; TRN: US0604293
Country of Publication:
United States
Language:
English

Similar Records

Discrimination Between Anthropogenic Sources of Atmospheric Radioxenon
Journal Article · Mon Dec 01 00:00:00 EST 2003 · Transactions of the American Nuclear Society, 87:89-90 · OSTI ID:888707

135Xe measurements with a two-element CZT-based radioxenon detector for nuclear explosion monitoring
Journal Article · Fri Feb 03 00:00:00 EST 2017 · Journal of Environmental Radioactivity · OSTI ID:888707

Redesigned ß–gamma Radioxenon Detector
Journal Article · Tue Aug 21 00:00:00 EDT 2007 · Nuclear Instruments and Methods in Physics Research. Section A: Accelerators, Spectrometers, Detectors and Associated Equipment · OSTI ID:888707