Bunch profiles in RHIC from CNI polarimeter target scans.
Abstract
During the RHIC run-4 polarized proton operation, the intensity and polarization profiles were measured by scanning the Coulomb-nuclear interference (CNI) polarimeter targets across the beam. The scans reported here were all performed on flattop at beam momenta {approx}100 GeV/c, and all but one was a vertical scan, since several of the vertical polarimeter targets had broken by the time of the measurements. This note summarizes some analyses of these profiles. Wall current monitor data are compared to these results for one beam and fill.
- Authors:
- Publication Date:
- Research Org.:
- Argonne National Lab. (ANL), Argonne, IL (United States)
- Sponsoring Org.:
- USDOE
- OSTI Identifier:
- 881579
- Report Number(s):
- ANL-HEP-TR-05-33
TRN: US0602931
- DOE Contract Number:
- W-31-109-ENG-38
- Resource Type:
- Technical Report
- Country of Publication:
- United States
- Language:
- ENGLISH
- Subject:
- 72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS; MONITORS; POLARIMETERS; POLARIZATION; PROTONS; TARGETS
Citation Formats
Spinka, H M. Bunch profiles in RHIC from CNI polarimeter target scans.. United States: N. p., 2005.
Web. doi:10.2172/881579.
Spinka, H M. Bunch profiles in RHIC from CNI polarimeter target scans.. United States. https://doi.org/10.2172/881579
Spinka, H M. 2005.
"Bunch profiles in RHIC from CNI polarimeter target scans.". United States. https://doi.org/10.2172/881579. https://www.osti.gov/servlets/purl/881579.
@article{osti_881579,
title = {Bunch profiles in RHIC from CNI polarimeter target scans.},
author = {Spinka, H M},
abstractNote = {During the RHIC run-4 polarized proton operation, the intensity and polarization profiles were measured by scanning the Coulomb-nuclear interference (CNI) polarimeter targets across the beam. The scans reported here were all performed on flattop at beam momenta {approx}100 GeV/c, and all but one was a vertical scan, since several of the vertical polarimeter targets had broken by the time of the measurements. This note summarizes some analyses of these profiles. Wall current monitor data are compared to these results for one beam and fill.},
doi = {10.2172/881579},
url = {https://www.osti.gov/biblio/881579},
journal = {},
number = ,
volume = ,
place = {United States},
year = {Fri Jun 03 00:00:00 EDT 2005},
month = {Fri Jun 03 00:00:00 EDT 2005}
}