Thermal-Hydrologic Sensitivity Analysis of Engineered Barrier System Design Options
This sensitivity study presents the effects that changing the ventilation time and initial linear power loading can have on specific thermal-hydrologic response parameters, such as waste package peak temperatures. Results show that an approximate 55 C drop in waste package peak temperature can be expected from the reference case design if the initial line loading is reduced to 0.90 kW/m or if the ventilation time is increased to 125 years. Increasing the waste package to waste package spacing in order to reduce the linear load to 0.90 kW/m requires additional emplacement drifts and an expansion of the area that the repository occupies. Increasing the ventilation duration requires that the repository remains open and is maintained for long periods of time. The effectiveness and expense of each design alternative must be weighed in determining the best way to achieve a particular thermal goal. Also, this sensitivity study shows that certain thermal goals may not be reached if only using ventilation, sometimes only the reduction of the linear load or a combination of linear loading and ventilation can reduce the thermal response to lower temperature specifications, if considered. As an example, Figure 1 shows that waste package peak temperatures below 96 C would require both a reduction in the linear load and an increase in ventilation duration.
- Research Organization:
- Yucca Mountain Project, Las Vegas, NV (United States)
- Sponsoring Organization:
- US Department of Energy (US)
- OSTI ID:
- 837025
- Report Number(s):
- NA; MOL.20010319.0377, DC 27244; TRN: US0502220
- Resource Relation:
- Other Information: PBD: 1 Nov 2000
- Country of Publication:
- United States
- Language:
- English
Similar Records
License Application Design Selection Enhanced Design Alternative V: Very High Thermal Loading
Design Evolution Study Thermal Operating Methodology