Title: Thermal Testing Measurements Report

Technical Report ·
DOI:https://doi.org/10.2172/836503· OSTI ID:836503

The purpose of the Thermal Testing Measurements Report (Scientific Analysis Report) is to document, in one report, the comprehensive set of measurements taken within the Yucca Mountain Project Thermal Testing Program since its inception in 1996. Currently, the testing performed and measurements collected are either scattered in many level 3 and level 4 milestone reports or, in the case of the ongoing Drift Scale Test, mostly documented in eight informal progress reports. Documentation in existing reports is uneven in level of detail and quality. Furthermore, while all the data collected within the Yucca Mountain Site Characterization Project (YMP) Thermal Testing Program have been submitted periodically to the Technical Data Management System (TDMS), the data structure--several incremental submittals, and documentation formats--are such that the data are often not user-friendly except to those who acquired and processed the data. The documentation in this report is intended to make data collected within the YMP Thermal Testing Program readily usable to end users, such as those representing the Performance Assessment Project, Repository Design Project, and Engineered Systems Sub-Project. Since either detailed level 3 and level 4 reports exist or the measurements are straightforward, only brief discussions are provided for each data set. These brief discussions for different data sets are intended to impart a clear sense of applicability of data, so that they will be used properly within the context of measurement uncertainty. This approach also keeps this report to a manageable size, an important consideration because the report encompasses nearly all measurements for three long-term thermal tests. As appropriate, thermal testing data currently residing in the TDMS have been reorganized and reformatted from cumbersome, user-unfriendly Input-Data Tracking Numbers (DTNs) into a new set of Output-DTNs. These Output-DTNs provide a readily usable data structure, including graphical displays and comprehensive spreadsheets. In some cases, there was no need to reformat or restructure Input-DTNs so they remained unchanged. Thermal testing measurement data come from the characterization (pre-heating/baseline and post-cooling) and testing (heating and cooling) phases of the Large Block Test (LBT), the Single Heater Test (SHT), and the Drift Scale Test (DST). Since the LBT and SHT are completed, all phases of those two tests are addressed. DST measurements addressed in this report include preheating and the entire four-year heating phase, which ended January 14, 2002. Discussion of measurements from the ongoing cooling phase will be included in future revision(s) of this report.

Research Organization:
Yucca Mountain Project, Las Vegas, NV (United States)
Sponsoring Organization:
US Department of Energy (US)
OSTI ID:
836503
Report Number(s):
ANL-NBS-HS-000041, Rev 00; MOL.20021004.0314, DC No. 32282; TRN: US0500721
Resource Relation:
Other Information: PBD: 26 Sep 2002
Country of Publication:
United States
Language:
English