Title: A CAVITY RING-DOWN SPECTROSCOPY MERCURY CONTINUOUS EMISSION MONITOR

Abstract

Previous work on the detection of mercury using the cavity ring-down (CRD) technique has concentrated on the detection and characterization of the desired mercury transition. Interferent species present in flue gas emissions have been tested as well as a simulated flue gas stream. Additionally, work has been done on different mercury species such as the elemental and oxidized forms. The next phase of the effort deals with the actual sampling system. This sampling system will be responsible for acquiring a sample stream from the flue gas stack, taking it to the CRD cavity where it will be analyzed and returning the gas stream to the stack. In the process of transporting the sample gas stream every effort must be taken to minimize any losses of mercury to the walls of the sampling system as well as maintaining the mercury in its specific state (i.e. elemental, oxidized, or other mercury compounds). SRD first evaluated a number of commercially available sampling systems. These systems ranged from a complete sampling system to a number of individual components for specific tasks. SRD engineers used some commercially available components and designed a sampling system suited to the needs of the CRD instrument. This included componentsmore » such as a pyrolysis oven to convert all forms of mercury to elemental mercury, a calibration air source to ensure mirror alignment and quality of the mirror surfaces, and a pumping system to maintain the CRD cavity pressure from atmospheric pressure (760 torr) down to about 50 torr. SRD also began evaluating methods for the CRD instrument to automatically find the center of a mercury transition. This procedure is necessary as the instrument must periodically measure the baseline losses of the cavity off of the mercury resonance and then return to the center of the transition to accurately measure the mercury concentration. This procedure is somewhat complicated due to the isotopic structure of the 254 nm mercury transition. As a result of 6 isotopes and hyperfine splittings there are 5 individual peaks that can be resolved by the CRD instrument. SRD tested a derivative method with both simulated data and actual data taken with the CRD apparatus. Initial tests indicate that this method is successful in automatically finding the center of the mercury transitions.« less

Authors:
Publication Date:
Research Org.:
Sensor Research and Development Corporation (US)
Sponsoring Org.:
(US)
OSTI Identifier:
821847
DOE Contract Number:  
FC26-01NT41221
Resource Type:
Technical Report
Resource Relation:
Other Information: PBD: 30 Jun 2003
Country of Publication:
United States
Language:
English
Subject:
54 ENVIRONMENTAL SCIENCES; 01 COAL, LIGNITE, AND PEAT; FLUE GAS; MERCURY; AIR POLLUTION MONITORS; PYROLYSIS; SPECTROSCOPY; AIR SAMPLERS

Citation Formats

Christopher C Carter, Ph D. A CAVITY RING-DOWN SPECTROSCOPY MERCURY CONTINUOUS EMISSION MONITOR. United States: N. p., 2003. Web. doi:10.2172/821847.
Christopher C Carter, Ph D. A CAVITY RING-DOWN SPECTROSCOPY MERCURY CONTINUOUS EMISSION MONITOR. United States. https://doi.org/10.2172/821847
Christopher C Carter, Ph D. 2003. "A CAVITY RING-DOWN SPECTROSCOPY MERCURY CONTINUOUS EMISSION MONITOR". United States. https://doi.org/10.2172/821847. https://www.osti.gov/servlets/purl/821847.
@article{osti_821847,
title = {A CAVITY RING-DOWN SPECTROSCOPY MERCURY CONTINUOUS EMISSION MONITOR},
author = {Christopher C Carter, Ph D},
abstractNote = {Previous work on the detection of mercury using the cavity ring-down (CRD) technique has concentrated on the detection and characterization of the desired mercury transition. Interferent species present in flue gas emissions have been tested as well as a simulated flue gas stream. Additionally, work has been done on different mercury species such as the elemental and oxidized forms. The next phase of the effort deals with the actual sampling system. This sampling system will be responsible for acquiring a sample stream from the flue gas stack, taking it to the CRD cavity where it will be analyzed and returning the gas stream to the stack. In the process of transporting the sample gas stream every effort must be taken to minimize any losses of mercury to the walls of the sampling system as well as maintaining the mercury in its specific state (i.e. elemental, oxidized, or other mercury compounds). SRD first evaluated a number of commercially available sampling systems. These systems ranged from a complete sampling system to a number of individual components for specific tasks. SRD engineers used some commercially available components and designed a sampling system suited to the needs of the CRD instrument. This included components such as a pyrolysis oven to convert all forms of mercury to elemental mercury, a calibration air source to ensure mirror alignment and quality of the mirror surfaces, and a pumping system to maintain the CRD cavity pressure from atmospheric pressure (760 torr) down to about 50 torr. SRD also began evaluating methods for the CRD instrument to automatically find the center of a mercury transition. This procedure is necessary as the instrument must periodically measure the baseline losses of the cavity off of the mercury resonance and then return to the center of the transition to accurately measure the mercury concentration. This procedure is somewhat complicated due to the isotopic structure of the 254 nm mercury transition. As a result of 6 isotopes and hyperfine splittings there are 5 individual peaks that can be resolved by the CRD instrument. SRD tested a derivative method with both simulated data and actual data taken with the CRD apparatus. Initial tests indicate that this method is successful in automatically finding the center of the mercury transitions.},
doi = {10.2172/821847},
url = {https://www.osti.gov/biblio/821847}, journal = {},
number = ,
volume = ,
place = {United States},
year = {Mon Jun 30 00:00:00 EDT 2003},
month = {Mon Jun 30 00:00:00 EDT 2003}
}