CH Packaging Operations for High Wattage Waste at LANL
This procedure provides instructions for assembling the following contact-handled (CH) packaging payloads: - Drum payload assembly - Standard Waste Box (SWB) assembly - Ten-Drum Overpack (TDOP) In addition, this procedure also provides operating instructions for the TRUPACT-II CH waste packaging. This document also provides instructions for performing ICV and OCV preshipment leakage rate tests on the following packaging seals, using a nondestructive helium (He) leak test: - ICV upper main O-ring seal - ICV outer vent port plug O-ring seal - OCV upper main O-ring seal - OCV vent port plug O-ring seal.
- Research Organization:
- Waste Isolation Pilot Plant, Carlsbad, NM (US)
- Sponsoring Organization:
- US Department of Energy (US)
- DOE Contract Number:
- 04-01A66444
- OSTI ID:
- 815193
- Report Number(s):
- DOE/WIPP 02-3220, Rev. 1; TRN: US0305230
- Resource Relation:
- Other Information: PBD: 18 Dec 2002
- Country of Publication:
- United States
- Language:
- English