Two-phase pressure drop across a straight test pipe was experimentally determined for high Reynolds (Re) number steam flow for a flow quality range of 0.995 to 1.0. The testing described has been performed in order to reduce uncertainties associated with the effects of two-phase flow on pressure drop. Two-phase flow develops in steam piping because a small fraction of the steam flow condenses due to heat loss to the surroundings. There has been very limited two-phase pressure drop data in open literature for the tested flow quality range. The two-phase pressure drop data obtained in this test has enabled development of a correlation between friction factor, Reynolds number, and flow quality.

Research Organization:
Bettis Atomic Power Lab., West Mifflin, PA (US)
Sponsoring Organization:
US Department of Energy (US)
DOE Contract Number:
AC11-98PN38206
OSTI ID:
807253
Report Number(s):
B-T-3390; TRN: US0401022
Resource Relation:
Conference: ASME Fluids Engineering Division, Montreal, Quebec (CA), 07/14/2002; Other Information: Supercedes report DE00807253; PBD: 1 Oct 2001; PBD: 1 Oct 2001
Country of Publication:
United States
Language:
English