Criticality Safety Evaluation of Hanford Site High Level Waste Storage Tanks
Abstract
This criticality safety evaluation covers operations for waste in underground storage tanks at the high-level waste tank farms on the Hanford site. This evaluation provides the bases for criticality safety limits and controls to govern receipt, transfer, and long-term storage of tank waste. Justification is provided that a nuclear criticality accident cannot occur for tank farms operations, based on current fissile material and operating conditions.
- Authors:
- Publication Date:
- Research Org.:
- CH2M Hill Hanford Group, Inc., Richland, WA (United States)
- Sponsoring Org.:
- ENVIRONMENTAL MANAGEMENT (US)
- OSTI Identifier:
- 801334
- Report Number(s):
- RPP-5296, Rev.0
EDT-628251; TRN: US0300400
- DOE Contract Number:
- AC27-99RL14047
- Resource Type:
- Technical Report
- Resource Relation:
- Other Information: PBD: 17 Feb 2000
- Country of Publication:
- United States
- Language:
- English
- Subject:
- 11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS; CRITICALITY; EVALUATION; FISSILE MATERIALS; RADIATION ACCIDENTS; SAFETY; STORAGE; STORAGE FACILITIES; TANKS; UNDERGROUND STORAGE; WASTE STORAGE; WASTES
Citation Formats
ROGERS, C A. Criticality Safety Evaluation of Hanford Site High Level Waste Storage Tanks. United States: N. p., 2000.
Web. doi:10.2172/801334.
ROGERS, C A. Criticality Safety Evaluation of Hanford Site High Level Waste Storage Tanks. United States. https://doi.org/10.2172/801334
ROGERS, C A. 2000.
"Criticality Safety Evaluation of Hanford Site High Level Waste Storage Tanks". United States. https://doi.org/10.2172/801334. https://www.osti.gov/servlets/purl/801334.
@article{osti_801334,
title = {Criticality Safety Evaluation of Hanford Site High Level Waste Storage Tanks},
author = {ROGERS, C A},
abstractNote = {This criticality safety evaluation covers operations for waste in underground storage tanks at the high-level waste tank farms on the Hanford site. This evaluation provides the bases for criticality safety limits and controls to govern receipt, transfer, and long-term storage of tank waste. Justification is provided that a nuclear criticality accident cannot occur for tank farms operations, based on current fissile material and operating conditions.},