Title: Evaluation of Need and Location for a Thermogravimetric Analyzer in the Plutonium Finishing Plant (PFP) Materials Stabilization

Abstract

This plan provides an analysis for locating a TGA to support PFP Thermal Stabilization processes. The scope of this document is to evaluate the need for, and location for, installation of a TGA system as a supplement to the SFE equipment for moisture measurement in pure oxides. A location assessment for the SFE equipment was previously performed (HNF 1999). Based on that assessment, co-location of the TGA system with the SFE system is the preferred option. This would enable thermally stabilized material to be analyzed for residual moisture by either the TGA system or SFE system or both This evaluation considers glovebox locations in the PFP 234-52 Building Analytical Laboratory or operating areas for the installation of the TGA system and it's supporting equipment. This evaluation considers using existing gloveboxes along with an alternative of adding a new glovebox to existing process lines. The location evaluation criteria focuses mainly on glovebox size, with qualitative consideration of relative cost and schedule impacts associated with system implementation, radiological control, and interaction with other laboratory operations and processes. In addition, the possible co-location of a TGA furnace system with the SFE system was considered.

Authors:
Publication Date:
Research Org.:
PENV (US)
Sponsoring Org.:
ENVIRONMENTAL MANAGEMENT (US)
OSTI Identifier:
801126
Report Number(s):
HNF-5641, Rev.0
TRN: US0300089
DOE Contract Number:  
AC06-96RL13200
Resource Type:
Technical Report
Resource Relation:
Other Information: PBD: 20 Jan 2000
Country of Publication:
United States
Language:
English
Subject:
11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS; GLOVEBOXES; MOISTURE; PLUTONIUM OXIDES; PLUTONIUM; STABILIZATION; THERMAL GRAVIMETRIC ANALYSIS; MEASURING INSTRUMENTS; SITE SELECTION; FUEL REPROCESSING PLANTS

Citation Formats

WILLIS, H T. Evaluation of Need and Location for a Thermogravimetric Analyzer in the Plutonium Finishing Plant (PFP) Materials Stabilization. United States: N. p., 2000. Web. doi:10.2172/801126.
WILLIS, H T. Evaluation of Need and Location for a Thermogravimetric Analyzer in the Plutonium Finishing Plant (PFP) Materials Stabilization. United States. https://doi.org/10.2172/801126
WILLIS, H T. 2000. "Evaluation of Need and Location for a Thermogravimetric Analyzer in the Plutonium Finishing Plant (PFP) Materials Stabilization". United States. https://doi.org/10.2172/801126. https://www.osti.gov/servlets/purl/801126.
@article{osti_801126,
title = {Evaluation of Need and Location for a Thermogravimetric Analyzer in the Plutonium Finishing Plant (PFP) Materials Stabilization},
author = {WILLIS, H T},
abstractNote = {This plan provides an analysis for locating a TGA to support PFP Thermal Stabilization processes. The scope of this document is to evaluate the need for, and location for, installation of a TGA system as a supplement to the SFE equipment for moisture measurement in pure oxides. A location assessment for the SFE equipment was previously performed (HNF 1999). Based on that assessment, co-location of the TGA system with the SFE system is the preferred option. This would enable thermally stabilized material to be analyzed for residual moisture by either the TGA system or SFE system or both This evaluation considers glovebox locations in the PFP 234-52 Building Analytical Laboratory or operating areas for the installation of the TGA system and it's supporting equipment. This evaluation considers using existing gloveboxes along with an alternative of adding a new glovebox to existing process lines. The location evaluation criteria focuses mainly on glovebox size, with qualitative consideration of relative cost and schedule impacts associated with system implementation, radiological control, and interaction with other laboratory operations and processes. In addition, the possible co-location of a TGA furnace system with the SFE system was considered.},
doi = {10.2172/801126},
url = {https://www.osti.gov/biblio/801126}, journal = {},
number = ,
volume = ,
place = {United States},
year = {Thu Jan 20 00:00:00 EST 2000},
month = {Thu Jan 20 00:00:00 EST 2000}
}