Gas Generation Testing of Plutonium Dioxide
Hydrogen and oxygen gas generation rates were measured for purified plutonium oxide (PuO2) powder as a function of water content, specific surface area (SSA), dose rate, and initial fill gas composition. Gas generation rates were found to increase with water content and dose rate and to decrease with specific surface area for given water content. Hydrogen generation rates were similar in air, nitrogen and argon, but oxygen generation rates were greater in nitrogen and argon than in air. The potential for reaching a steady state container pressure for PuO2 of given calcination temperature (i.e., SSA) and water content was evaluated by adding hydrogen to some test vessels and monitoring the effect on container pressure over time
- Research Organization:
- Savannah River Site (SRS), Aiken, SC (United States)
- Sponsoring Organization:
- US Department of Energy (US)
- DOE Contract Number:
- AC09-96SR18500
- OSTI ID:
- 800730
- Report Number(s):
- WSRC-MS-2002-00705; TRN: US0206413
- Resource Relation:
- Conference: 5th Topical Meeting on Spent Nuclear Fuel and Fissile, Charleston, SC (US), 09/17/2002--09/20/2002; Other Information: PBD: 29 Aug 2002
- Country of Publication:
- United States
- Language:
- English
Similar Records
MIS High-Purity Plutonium Oxide Metal Oxidation Product BLO-39-11-14-004 (SSR132 and 132A): Final Report