Title: Uranium Measurement Improvements at the Savannah River Technology Center

Abstract

Uranium isotope ratio and isotope dilution methods by mass spectrometry are used to achieve sensitivity, precision and accuracy for various applications. This report presents recent progress made at SRTC in the analysis of minor isotopes of uranium. Comparison of routine measurements of NBL certified uranium (U005a) using the SRTC Three Stage Mass Spectrometer (3SMS) and the SRTC Single Stage Mass Spectrometer (SSMS). As expected, the three stage mass spectrometer yielded superior sensitivity, precision, and accuracy for this application.

Authors:
Publication Date:
Research Org.:
Savannah River Site (SRS), Aiken, SC (United States)
Sponsoring Org.:
US Department of Energy (US)
OSTI Identifier:
799322
Report Number(s):
WSRC-MS-2002-00087
TRN: US0300018
DOE Contract Number:  
AC09-96SR18500
Resource Type:
Conference
Resource Relation:
Conference: American Nuclear Society 2002 Annual Meeting, Hollywood, FL (US), 06/09/2002--06/13/2002; Other Information: PBD: 13 Feb 2002
Country of Publication:
United States
Language:
English
Subject:
38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEAR CHEMISTRY; ACCURACY; ISOTOPE DILUTION; MASS SPECTROMETERS; SAVANNAH RIVER PLANT; SENSITIVITY; URANIUM; URANIUM ISOTOPES; ISOTOPE RATIO; PERFORMANCE

Citation Formats

Shick, C Jr. Uranium Measurement Improvements at the Savannah River Technology Center. United States: N. p., 2002. Web.
Shick, C Jr. Uranium Measurement Improvements at the Savannah River Technology Center. United States.
Shick, C Jr. 2002. "Uranium Measurement Improvements at the Savannah River Technology Center". United States. https://www.osti.gov/servlets/purl/799322.
@article{osti_799322,
title = {Uranium Measurement Improvements at the Savannah River Technology Center},
author = {Shick, C Jr},
abstractNote = {Uranium isotope ratio and isotope dilution methods by mass spectrometry are used to achieve sensitivity, precision and accuracy for various applications. This report presents recent progress made at SRTC in the analysis of minor isotopes of uranium. Comparison of routine measurements of NBL certified uranium (U005a) using the SRTC Three Stage Mass Spectrometer (3SMS) and the SRTC Single Stage Mass Spectrometer (SSMS). As expected, the three stage mass spectrometer yielded superior sensitivity, precision, and accuracy for this application.},
doi = {},
url = {https://www.osti.gov/biblio/799322}, journal = {},
number = ,
volume = ,
place = {United States},
year = {Wed Feb 13 00:00:00 EST 2002},