Title: Project W-314 updated acceptance test report HNF-4649 for HNF-4648 241-AN-A pit leak detection ANA-WT-LDSTA-331 for project W-314

Technical Report ·
DOI:https://doi.org/10.2172/798032· OSTI ID:798032

The purpose of the test was to verify that the AN Tank Farm AN-A Pit Leak Detector components are functionally integrated and operate in accordance with engineering design specifications. The Acceptance Test Procedure HNF-4648,24l-AN-A-Pit Leak Detection ANA-WT-LDSTA-331 was conducted between 23 June and 01 July 1999 at the 200E AN Tank Farm. The test has been completed with no open test exceptions. The test was conducted prior to final engineering ''as built'' activities being completed this had no impact on the procedure or test results. All components, identified in the procedure were found to be labeled and identified as written in the procedure.