skip to main content
OSTI.GOV title logo U.S. Department of Energy
Office of Scientific and Technical Information

Title: Vadose Zone Remediation Assessment: M-Area Process Sewer Soil Vapor Extraction Units 782-5M, 782-7M, and 782-8M

Technical Report ·
DOI:https://doi.org/10.2172/779697· OSTI ID:779697

This study focuses on the status of the vadose zone remediation along 1600 ft of the process sewer line between the M-Area security fence and the M-Area settling basin. Three soil vapor extraction (SVE) units 782-5M, 782-7M, and 782-8M, connected to 4 vertical wells and 3 horizontal wells have been addressing the vadose zone volatile organic contamination (VOC) since 1995. The specific objectives of this study were to obtain soil gas and sediment samples, evaluate SVE units and vadose zone remediation, and make recommendations to address further remediation needs.

Research Organization:
Savannah River Site (SRS), Aiken, SC (United States)
Sponsoring Organization:
US Department of Energy (US)
DOE Contract Number:
AC09-96SR18500
OSTI ID:
779697
Report Number(s):
WSRC-TR-2001-00077; TRN: AH200120%%164
Resource Relation:
Other Information: PBD: 20 Apr 2001
Country of Publication:
United States
Language:
English