The Effect of Carbonate, Oxalate and Peroxide on the Cesium Loading of Ionsiv IE-910 and IE-911
The Savannah River Site (SRS) continues to examine three processes for the removal of radiocesium from high-level waste. One option involves the use of crystalline silicotitanate (CST) as a non-elutable ion exchange medium. The process uses CST in its engineered form - IONSIV IE-911 made by UOP, LLC. - in a column to contact the liquid waste. Cesium exchanges with sodium ions residing inside the CST particles. The design disposes of the cesium-loaded CST by vitrification within the Defense Waste Processing Facility.
- Research Organization:
- Savannah River Site (SRS), Aiken, SC (United States)
- Sponsoring Organization:
- US Department of Energy (US)
- DOE Contract Number:
- AC09-96SR18500
- OSTI ID:
- 773108
- Report Number(s):
- WSRC-TR-2000-00344; TRN: US0100041
- Resource Relation:
- Other Information: PBD: 19 Dec 2000
- Country of Publication:
- United States
- Language:
- English
Similar Records
The Effect of Pressure and Organic Constituents on the Cesium Ion Exchange Performance of IONSIV IE-911
Ion Exchange Modeling of Crystalline Silicotitanate (IONSIV(R) IE-911) Column for Cesium Removal from Argentine Waste
Removal of Cesium From Acidic Radioactive Tank Waste Using IONSIV IE-911 (CST)
Technical Report
·
Tue Jul 18 00:00:00 EDT 2000
·
OSTI ID:773108
Ion Exchange Modeling of Crystalline Silicotitanate (IONSIV(R) IE-911) Column for Cesium Removal from Argentine Waste
Technical Report
·
Wed Jul 16 00:00:00 EDT 2003
·
OSTI ID:773108
Removal of Cesium From Acidic Radioactive Tank Waste Using IONSIV IE-911 (CST)
Journal Article
·
Fri Oct 01 00:00:00 EDT 2004
· Separation Science and Technology
·