skip to main content
OSTI.GOV title logo U.S. Department of Energy
Office of Scientific and Technical Information

Title: Assessment of Donlee 3000-horsepower TurboFireXL boiler. Technology Installation Review

Technical Report ·
DOI:https://doi.org/10.2172/770623· OSTI ID:770623

This 'Technology Installation Review' (TIR) describes the TurboFireXL industrial boiler technology and presents information on existing applications, energy-saving mechanisms, installation requirements, and relevant case studies.

Research Organization:
Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States)
Sponsoring Organization:
USDOE Office of Energy Efficiency and Renewable Energy (EE), Federal Energy Management Program (US)
OSTI ID:
770623
Report Number(s):
DOE/EE-0217; TRN: AH200135%%4
Resource Relation:
Other Information: PBD: 1 May 2000
Country of Publication:
United States
Language:
English