skip to main content
OSTI.GOV title logo U.S. Department of Energy
Office of Scientific and Technical Information

Title: Hydrofluoric Acid Corrosion Testing on Unplated and Electroless Gold-Plated Samples

Technical Report ·
DOI:https://doi.org/10.2172/763206· OSTI ID:763206

The Molten Salt Reactor Experiment (MSRE) remediation requires that almost 40 kg of uranium hexafluoride (UF6) be converted to uranium oxide (UO). In the process of this conversion, six moles of hydrofluoric acid (HP) are produced for each mole of UF6 converted.

Research Organization:
Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States)
Sponsoring Organization:
USDOE Office of Science (US)
DOE Contract Number:
AC05-00OR22725
OSTI ID:
763206
Report Number(s):
ORNL/TM-2000/137; TRN: US0005075
Resource Relation:
Other Information: PBD: 1 Aug 2000
Country of Publication:
United States
Language:
English