Transuranium Removal from Hanford AN-107 Simulants using Sodium Permanganate and Calcium
Removal of strontium from the complexant-containing wastes (AN-102 and AN-107) had previously been acceptably accomplished by isotopic dilution. Actinide removal using ferric co-precipitation, however, was very problematic from both a processing and a decontamination standpoint. Therefore, a series of tests were performed to identify other potential actinide removal agents and to test these agents at various concentrations.
- Research Organization:
- Savannah River Site (SRS), Aiken, SC (United States)
- Sponsoring Organization:
- US Department of Energy (US)
- DOE Contract Number:
- AC09-96SR18500
- OSTI ID:
- 761641
- Report Number(s):
- BNF-003-98-0160, Rev, 0; TRN: US0005406
- Resource Relation:
- Other Information: PBD: 30 Aug 2000
- Country of Publication:
- United States
- Language:
- English
Similar Records
Hanford Sr/TRU Decontamination Program: Research from Beaker to Pilot Scale
Waste Treatment Technology Process Development Plan For Hanford Waste Treatment Plant Low Activity Waste Recycle
LABORATORY OPTIMIZATION TESTS OF TECHNETIUM DECONTAMINATION OF HANFORD WASTE TREATMENT PLANT LOW ACTIVITY WASTE OFF-GAS CONDENSATE SIMULANT
Conference
·
Tue Feb 18 00:00:00 EST 2003
·
OSTI ID:761641
Waste Treatment Technology Process Development Plan For Hanford Waste Treatment Plant Low Activity Waste Recycle
Technical Report
·
Thu Aug 29 00:00:00 EDT 2013
·
OSTI ID:761641
LABORATORY OPTIMIZATION TESTS OF TECHNETIUM DECONTAMINATION OF HANFORD WASTE TREATMENT PLANT LOW ACTIVITY WASTE OFF-GAS CONDENSATE SIMULANT
Technical Report
·
Mon Sep 29 00:00:00 EDT 2014
·
OSTI ID:761641