Title: High heat-load absorbers for the APS storage ring

Conference ·
OSTI ID:759077

The power density of the dipole x-rays in the 7-GeV APS storage ring is 261 watts/mrad at 300 mA of beam current. An array of absorbers is used in the ring to shield its vacuum chambers and diagnostics components in the path of these intense x-rays. This paper describes some of the unique absorber designs that were developed to handle the requirements of high power density and UHV compatibility with no water-to-vacuum joints.

Research Organization:
Argonne National Lab., IL (US)
Sponsoring Organization:
US Department of Energy (US)
DOE Contract Number:
W-31109-ENG-38
OSTI ID:
759077
Report Number(s):
ANL/ASD/CP-102380; TRN: US0004481
Resource Relation:
Conference: MEDSI 2000, Villigen (CH), 07/13/2000--07/14/2000; Other Information: PBD: 21 Jul 2000
Country of Publication:
United States
Language: