Analytical results of Tank 38H core samples -- Fall 1999
Two samples were pulled from Tank 38H in the Fall of 1999: a variable depth sample (VDS) of the supernate was pulled in October and a core sample from the salt layer was pulled in December. Analysis of the rinse from the outside of the core sample indicated no sign of volatile or semivolatile organics. Both supernate and solids from the VDS and the dried core sample solids were analyzed for isotopes which could pose a criticality concern and also for elements which could serve as neutron poisons, as well as other elements. Results of the elemental analyses of these samples show significant elements present to mitigate the potential for nuclear criticality. However, it should be noted the results given for the VDS solids elemental analyses may be higher than the actual concentration in the solids, since the filter paper was dissolved along with the sample solids.
- Research Organization:
- Savannah River Site (SRS), Aiken, SC (United States)
- Sponsoring Organization:
- US Department of Energy (US)
- DOE Contract Number:
- AC09-96SR18500
- OSTI ID:
- 758310
- Report Number(s):
- WSRC-TR-2000-00064/Rev.0; TRN: US0003806
- Resource Relation:
- Other Information: PBD: 11 Jul 2000
- Country of Publication:
- United States
- Language:
- English