skip to main content
OSTI.GOV title logo U.S. Department of Energy
Office of Scientific and Technical Information

Title: Constant extension rate testing of Type 304L stainless steel in simulated waste tank environments. [Type 304L stainless steel]

Conference ·
DOI:https://doi.org/10.2172/10167211· OSTI ID:7171846

New tanks for storage of low level radioactive wastes will be constructed at the Savannah River Site (SRS) of AISI Type 304L stainless steel (304L). The presence of chlorides and fluorides in the wastes may induce Stress Corrosion Cracking (SCC) in 304L. Constant Extension Rate Tests (CERT) were performed to determine the susceptibility of 304L to SCC in simulated wastes. In five of the six tests conducted thus far 304L was not susceptible to SCC in the simulated waste environments. Conflicting results were obtained in the final test and will be resolved by further tests. For comparison purposes the CERT tests were also performed with A537 carbon steel, a material similar to that utilized for the existing nuclear waste storage tanks at SRS.

Research Organization:
Westinghouse Savannah River Co., Aiken, SC (United States)
Sponsoring Organization:
USDOE; USDOE, Washington, DC (United States)
DOE Contract Number:
AC09-89SR18035
OSTI ID:
7171846
Report Number(s):
WSRC-MS-91-511; CONF-920458-11; ON: DE93002807
Resource Relation:
Conference: Corrosion '92 conference and exhibition, Nashville, TN (United States), 27 Apr - 1 May 1992
Country of Publication:
United States
Language:
English