skip to main content
OSTI.GOV title logo U.S. Department of Energy
Office of Scientific and Technical Information

Title: A discussion of certain safety issues associated with the Tank 241-SY-101 mitigation mixing test

Abstract

This paper addresses certain safety issues associated with the Hanford Tank 241-SY 101 hydrogen mitigation mixing test. Specifically, the study, is concerned with the effect of pump shearing, jet mixing, and piling-up on the following areas: Gas generation; gas retention; gas release (immediate); gas release (long-term); and saltcake. The findings for each issue area of concern are addressed.

Publication Date:
Research Org.:
Pacific Northwest National Lab. (PNNL), Richland, WA (United States)
Sponsoring Org.:
USDOE; USDOE, Washington, DC (United States)
OSTI Identifier:
6812925
Report Number(s):
PNL-8354
ON: DE93003215
DOE Contract Number:  
AC06-76RL01830
Resource Type:
Technical Report
Country of Publication:
United States
Language:
English
Subject:
12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE WASTES FROM NUCLEAR FACILITIES; 11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS; GASES; MIXING; HIGH-LEVEL RADIOACTIVE WASTES; UNDERGROUND STORAGE; CHEMICAL REACTIONS; FLAMMABILITY; HANFORD RESERVATION; HYDROGEN; PUMPS; SAFETY; SOLIDS; TANKS; COMBUSTION PROPERTIES; CONTAINERS; ELEMENTS; FLUIDS; MATERIALS; NATIONAL ORGANIZATIONS; NONMETALS; RADIOACTIVE MATERIALS; RADIOACTIVE WASTES; STORAGE; US DOE; US ERDA; US ORGANIZATIONS; WASTES; 052002* - Nuclear Fuels- Waste Disposal & Storage; 054000 - Nuclear Fuels- Health & Safety

Citation Formats

. A discussion of certain safety issues associated with the Tank 241-SY-101 mitigation mixing test. United States: N. p., 1992. Web. doi:10.2172/6812925.
. A discussion of certain safety issues associated with the Tank 241-SY-101 mitigation mixing test. United States. https://doi.org/10.2172/6812925
. 1992. "A discussion of certain safety issues associated with the Tank 241-SY-101 mitigation mixing test". United States. https://doi.org/10.2172/6812925. https://www.osti.gov/servlets/purl/6812925.
@article{osti_6812925,
title = {A discussion of certain safety issues associated with the Tank 241-SY-101 mitigation mixing test},
author = {},
abstractNote = {This paper addresses certain safety issues associated with the Hanford Tank 241-SY 101 hydrogen mitigation mixing test. Specifically, the study, is concerned with the effect of pump shearing, jet mixing, and piling-up on the following areas: Gas generation; gas retention; gas release (immediate); gas release (long-term); and saltcake. The findings for each issue area of concern are addressed.},
doi = {10.2172/6812925},
url = {https://www.osti.gov/biblio/6812925}, journal = {},
number = ,
volume = ,
place = {United States},
year = {Tue Sep 01 00:00:00 EDT 1992},
month = {Tue Sep 01 00:00:00 EDT 1992}
}