TLD's replaced film badges in the early 1970's for all dose equivalent monitoring, both neutron and photon, and for all locations at SLAC. The photon TLD's, composed of Li-7 loaded teflon discs, are calibrated using conventional gamma-ray sources; i.e., Co-60, Cs-137, etc. For these TLD's a nominal value of 1 nC/mrem is used, and is independent of source energy for 100 keV to 3 MeV. Since measured dose equivalents at SLAC are only a small fraction of the allowable levels, it was not deemed necessary to develop neutron dosimeters which would measure dose equivalent accurately for all possible neutron spectra. Today, wallet TLD's, composed of pairs of Li-7 and Li-6 discs, are used, with the Li-6 measuring only thermal neutrons; i.e., they aren't moderated in any way to make them sensitive to neutrons with energies greater than thermal. The assumption is made that there is a correlation between thermal neutron fluences and fast neutron fluences around the research area where almost all neutron doses (exclusive of sealed sources) are received. The calibration factor for these Li-6 TLD's is 1 nC/mrem of fast neutrons. The method of determining the validity of this calibration is the subject of this note. 4 refs.,more » 9 figs., 1 tab.« less

Authors:
;
Publication Date:
Research Org.:
SLAC National Accelerator Lab., Menlo Park, CA (United States)
OSTI Identifier:
6641947
Report Number(s):
SLAC-TN-87-2
ON: DE87008762
DOE Contract Number:  
AC03-76SF00515
Resource Type:
Technical Report
Resource Relation:
Other Information: Portions of this document are illegible in microfiche products
Country of Publication:
United States
Language:
English
Subject:
63 RADIATION, THERMAL, AND OTHER ENVIRON. POLLUTANT EFFECTS ON LIVING ORGS. AND BIOL. MAT.; 43 PARTICLE ACCELERATORS; STANFORD LINEAR COLLIDER; RADIATION PROTECTION; THERMOLUMINESCENT DOSIMETRY; PERFORMANCE TESTING; DOSE EQUIVALENTS; GAMMA DOSIMETRY; LITHIUM FLUORIDES; NEUTRON DOSIMETRY; ACCELERATOR FACILITIES; ACCELERATORS; ALKALI METAL COMPOUNDS; DOSIMETRY; FLUORIDES; FLUORINE COMPOUNDS; HALIDES; HALOGEN COMPOUNDS; LINEAR ACCELERATORS; LITHIUM COMPOUNDS; LITHIUM HALIDES; TESTING; 560151* - Radiation Effects on Animals- Man; 430000 - Particle Accelerators

Citation Formats

Jenkins, T M, and Busick, D D. Personnel dose equivalent monitoring at SLAC using lithium-fluoride TLD's (thermoluminescent dosimeters). United States: N. p., 1987. Web. doi:10.2172/6641947.
Jenkins, T M, & Busick, D D. Personnel dose equivalent monitoring at SLAC using lithium-fluoride TLD's (thermoluminescent dosimeters). United States. https://doi.org/10.2172/6641947
Jenkins, T M, and Busick, D D. 1987. "Personnel dose equivalent monitoring at SLAC using lithium-fluoride TLD's (thermoluminescent dosimeters)". United States. https://doi.org/10.2172/6641947. https://www.osti.gov/servlets/purl/6641947.
@article{osti_6641947,
title = {Personnel dose equivalent monitoring at SLAC using lithium-fluoride TLD's (thermoluminescent dosimeters)},
author = {Jenkins, T M and Busick, D D},
abstractNote = {TLD's replaced film badges in the early 1970's for all dose equivalent monitoring, both neutron and photon, and for all locations at SLAC. The photon TLD's, composed of Li-7 loaded teflon discs, are calibrated using conventional gamma-ray sources; i.e., Co-60, Cs-137, etc. For these TLD's a nominal value of 1 nC/mrem is used, and is independent of source energy for 100 keV to 3 MeV. Since measured dose equivalents at SLAC are only a small fraction of the allowable levels, it was not deemed necessary to develop neutron dosimeters which would measure dose equivalent accurately for all possible neutron spectra. Today, wallet TLD's, composed of pairs of Li-7 and Li-6 discs, are used, with the Li-6 measuring only thermal neutrons; i.e., they aren't moderated in any way to make them sensitive to neutrons with energies greater than thermal. The assumption is made that there is a correlation between thermal neutron fluences and fast neutron fluences around the research area where almost all neutron doses (exclusive of sealed sources) are received. The calibration factor for these Li-6 TLD's is 1 nC/mrem of fast neutrons. The method of determining the validity of this calibration is the subject of this note. 4 refs., 9 figs., 1 tab.},
doi = {10.2172/6641947},
url = {https://www.osti.gov/biblio/6641947}, journal = {},
number = ,
volume = ,
place = {United States},
year = {Sun Mar 01 00:00:00 EST 1987},
month = {Sun Mar 01 00:00:00 EST 1987}
}