Standpipe-bubbler pump level-control study sodium temperature distribution (task B)
A thermal analysis was performed to establish requirements for a heating system for the standpipe bubbler sufficient to maintain the sodium in the standpipe in a liquid condition over the range of operating conditions. There are very few formal requirements on operating limits or hardware selection. Therefore, consideration was given to standard types of equipment employed in a conventional manner. The recommended heating system consists of metal-sheathed resistance heaters with three units being mounted on standoffs and equally spaced around the pipe. The heaters would be covered by a layer of insulation having both interior and exterior coverings of reflective metal sheathing. The pipe temperature would be monitored by thermocouples, and the heaters would be turned on and off on a cycle of approximately 4 hours to maintain the pipe at a temperature of 800/sup 0/F +- 50/sup 0/F.
- Research Organization:
- Borg-Warner Corp., Los Angeles, CA (USA). Byron Jackson Pump Div.
- DOE Contract Number:
- AT03-76SF98001
- OSTI ID:
- 6371643
- Report Number(s):
- DOE/SF/98001-T6; ON: DE81023599
- Country of Publication:
- United States
- Language:
- English
Similar Records
EM 0211: standpipe-bubbler pump level control study, cover gas system analysis, (TASK B), W. P. 7373. [LMFBR]
Standpipe-bubbler pump level control study: 1E-3862, controlled clearance pump/system Model W. P. 7373. [LMFBR]
Related Subjects
LMFBR TYPE REACTORS
PUMPS
REACTOR COOLING SYSTEMS
BAFFLES
HEATERS
HIGH TEMPERATURE
PIPES
SODIUM
THERMOCOUPLES
ALKALI METALS
BREEDER REACTORS
CONTROL EQUIPMENT
COOLING SYSTEMS
ELEMENTS
ENERGY SYSTEMS
EPITHERMAL REACTORS
EQUIPMENT
FAST REACTORS
FBR TYPE REACTORS
FLOW REGULATORS
LIQUID METAL COOLED REACTORS
MEASURING INSTRUMENTS
METALS
REACTOR COMPONENTS
REACTORS
210500* - Power Reactors
Breeding