Title: Supercritical water oxidation technology for DWPF. [Defense Waste Processing Facility (DWPF)]

Technical Report ·
DOI:https://doi.org/10.2172/6367353· OSTI ID:6367353

At the request of Mr. H.L. Brandt and others in the Savannah River Field Office High Level Waste Division office, DWPF, and SRL personnel have reviewed two potential applications for supercritical water oxidation technology in DWPF. The first application would replace the current hydrolysis process by destroying the organic fractions of the precipitated cesium / potassium tetraphenylborate slurry. The second application pertains to liquid benzene destruction. After a thorough evaluation the first application is not recommended. The second is ready to be tested if needed.

Research Organization:
Savannah River Site (SRS), Aiken, SC (United States)
Sponsoring Organization:
USDOE; USDOE, Washington, DC (United States)
DOE Contract Number:
AC09-89SR18035
OSTI ID:
6367353
Report Number(s):
WSRC-RP-92-252; ON: DE93015382
Country of Publication:
United States
Language:
English