Title: In-plant test and evaluation of the neutron collar for verification of PWR fuel assemblies at Resende, Brazil

Technical Report ·
DOI:https://doi.org/10.2172/6265671· OSTI ID:6265671

The neutron-coincidence collar has been evaluated for the measurement of pressurized-water reactor (PWR) fuel assemblies at the Fabrica de Elementos Combustiveis plant in Resende, Brazil. This evaluation was part of the cooperative-bilateral-safeguards technical-exchange program between the United States and Brazil. The neutron collar measures the STVU content per unit length of full fuel assemblies using neutron interrogation and coincidence counting. The STYU content is measured in the passive mode without the AmLi neutron-interrogation source. The extended evaluation took place over a period of 6 months with both scanning and single-zone measurements. The results of the tests gave a coincidence-response standard deviation of 0.7% (sigma = 1.49% for mass) for the active case and 2.5% for the passive case in 1000-s measurement times. The length measurement in the scanning mode was accurate to 0.77%. The accuracies of different calibration methods were evaluated and compared.

Research Organization:
Los Alamos National Lab. (LANL), Los Alamos, NM (United States)
DOE Contract Number:
W-7405-ENG-36
OSTI ID:
6265671
Report Number(s):
LA-10562-MS; ON: DE86005860
Country of Publication:
United States
Language:
English