The new flash x-ray machine (FXR) at Lawrence Livermore National Laboratory is scheduled for completion in late 1981. This is a 54 module, linear induction accelertor, designed to deliver 500 Roentgen at 1 m as bremsstrahlung from a 20 MeV, 4 kA, 60 ns pulsed electron beam. The 9 cm diameter, cold-cathode electron source generates a 15 kA emitted beam at 1.5 MeV, and collimation is being used to reduce the transmitted current to 3.5 kA, with an emittance of 70 mr-cm. The collimated beam diameter is 4 cm. Six ferrite-loaded cavities are used in tandem to energize the injector. The high voltage performance of the injector cavities and other pulsed-power conditioning elements was tested earlier in a series of 10/sup 5/ shots at 400 kV per cavity. An overview of the injector design and of the beam test results is given.

Research Organization:
Lawrence Livermore National Lab., CA (USA)
DOE Contract Number:
W-7405-ENG-48
OSTI ID:
6200805
Report Number(s):
UCRL-85557; CONF-810620-14; ON: DE81027437; TRN: 81-014133
Resource Relation:
Conference: 4. international topical conference on high-power electron and ion-beam research and technology, Palaiseau, France, 29 Jun 1981
Country of Publication:
United States
Language:
English