Analysis and testing of the HP-R-214 dome monitor cable from Three Mile Island Unit 2
After the accident at Three Mile Island, Unit 2, two sections of a cable connected to the HP-R-214 dome monitor were removed for testing. One section had been directly exposed to the accident environment: the other had been installed in conduit. In addition, an unused section of cable, which was from the same reel as the dome monitor cable, was available as a control sample. These three sections were subjected to material tests, including density profiling, tensile-strength and elongation tests, and chemical analyses, to assess the effect of the accident on the cable and to identify whether any differences existed between the in-conduit and out-of-conduit sections.
- Research Organization:
- Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)
- Sponsoring Organization:
- USDOE
- DOE Contract Number:
- AC07-76ID01570
- OSTI ID:
- 5914550
- Report Number(s):
- GEND-INF-072; ON: DE86009093; TRN: 86-012694
- Resource Relation:
- Other Information: Portions of this document are illegible in microfiche products
- Country of Publication:
- United States
- Language:
- English
Similar Records
Examination results of the Three Mile Island radiation detector HP-R-211
Analysis of the TMI-2 dome radiation monitor
Examination results of the Three Mile Island radiation detector HP-R-211
Technical Report
·
Thu Oct 01 00:00:00 EDT 1981
·
OSTI ID:5914550
Analysis of the TMI-2 dome radiation monitor
Technical Report
·
Thu Aug 01 00:00:00 EDT 1985
·
OSTI ID:5914550
Examination results of the Three Mile Island radiation detector HP-R-211
Technical Report
·
Tue Sep 01 00:00:00 EDT 1981
·
OSTI ID:5914550
Related Subjects
21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS
THREE MILE ISLAND-2 REACTOR
ELECTRIC CABLES
DECONTAMINATION
EVALUATION
MONITORS
TENSILE PROPERTIES
TESTING
CABLES
CLEANING
CONDUCTOR DEVICES
ELECTRICAL EQUIPMENT
ENRICHED URANIUM REACTORS
EQUIPMENT
MEASURING INSTRUMENTS
MECHANICAL PROPERTIES
POWER REACTORS
PWR TYPE REACTORS
REACTORS
THERMAL REACTORS
WATER COOLED REACTORS
WATER MODERATED REACTORS
210200* - Power Reactors
Nonbreeding
Light-Water Moderated
Nonboiling Water Cooled
THREE MILE ISLAND-2 REACTOR
ELECTRIC CABLES
DECONTAMINATION
EVALUATION
MONITORS
TENSILE PROPERTIES
TESTING
CABLES
CLEANING
CONDUCTOR DEVICES
ELECTRICAL EQUIPMENT
ENRICHED URANIUM REACTORS
EQUIPMENT
MEASURING INSTRUMENTS
MECHANICAL PROPERTIES
POWER REACTORS
PWR TYPE REACTORS
REACTORS
THERMAL REACTORS
WATER COOLED REACTORS
WATER MODERATED REACTORS
210200* - Power Reactors
Nonbreeding
Light-Water Moderated
Nonboiling Water Cooled