Five metallization procedures were evaluated to determine a manufacturing process that would produce the most solderable and reliable Kovar lead frame package. From the metallization procedures examined, it was determined that: (1) silver-copper brazes lead to liquid-metal embrittlement of the metallized Kovar; (2) nickel electroplating of the Kovar reduces, but does not eliminate, copper penetration from the silver-copper braze; (3) low cobalt-nickel electrodeposits appear to be a better diffusion barrier than high cobalt-nickel compositions: (4) nickel electroplating of the Kovar lead increases nickel contamination on the gold surface; and (5) gold plating uniformity and porosity are of major concern in lead frame processing.