Title: Clinch River Breeder Reactor Plant steam generator: FEW tube test model post test examination

Conference ·
OSTI ID:5461282

The Steam Generator Few Tube Test (FTT) is part of an extensive testing program being carried out in support of the Clinch River Breeder Reactor Plant (CRBRP) steam generator design. The testing of full-length seven-tube evaporator and three-tube superheater models of the CRBRP design was conducted to provide steady-state thermal/hydraulic performance data to full power per tube and to verify the absence of multi-year endurance problems. The problems encountered with the mechanical features of the FTT model design which led to premature test termination and the results of the post-test examination are described.

Research Organization:
General Electric Co., Sunnyvale, CA (USA). Advanced Reactor Systems Dept.
DOE Contract Number:
EY-76-C-03-0189-061
OSTI ID:
5461282
Report Number(s):
CRBRP-GEFR-SP-176; CONF-800401-10; TRN: 80-009366
Resource Relation:
Conference: 2. international conference of liquid metal technology for energy systems, Richland, WA, USA, 20 Apr 1980
Country of Publication:
United States
Language:
English