skip to main content
OSTI.GOV title logo U.S. Department of Energy
Office of Scientific and Technical Information

Title: An evaluation of the susceptibility of V-4Cr-4Ti to stress corrosion cracking in room temperature DIII-D water

Technical Report ·
DOI:https://doi.org/10.2172/543269· OSTI ID:543269
;  [1];
  1. Pacific Northwest National Lab., Richland, WA (United States)

Two fatigue precracked compact tension (CT) specimens of V-4Cr-4Ti were statically loaded to a stress intensity factor of about 30 MPa{radical}m in room temperature DIII-D water. The first specimen was tested for a period of about 30 days and the second specimen for about 54 days. At the conclusion of each test the specimens were fractured, and the fracture surfaces examined with a scanning electron microscope (SEM) to determine if SCC had occurred. No SCC was found in either test specimen.

Research Organization:
Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States)
OSTI ID:
543269
Report Number(s):
DOE/ER-0313/21; ON: DE97008798; TRN: 97:020310
Resource Relation:
Other Information: PBD: Apr 1997; Related Information: Is Part Of Fusion materials semiannual progress report for the period ending December 31, 1996; PB: 296 p.
Country of Publication:
United States
Language:
English