Area monitoring dosimeter program for the Pacific Northwest National Laboratory: Results for CY 1996
Abstract
In January 1993, Pacific Northwest National Laboratory (PNNL) established an area monitoring dosimeter program in accordance with Article 514 of the Department of Energy (DOE) Radiological Control Manual (RCM). The purpose of the program was to minimize the number of areas requiring issuance of personnel dosimeters and to demonstrate that doses outside Radiological buffer Areas are negligible. In accordance with 10 CFR Part 835.402 (a) (1)-(3) and Article 511.1 of the RCM, personnel dosimetry shall be provided to (1) radiological workers who are likely to receive at least 100 mrem annually and (2) declared pregnant workers, minors, and members of the public who are likely to receive at least 50 mrem annually. Program results for calendar years 1993, 1994, and 1995 confirmed that personnel dosimetry was not needed for individuals located in areas monitored by the program. A total of 108 area TLDs were placed in PNNL facilities during CY 1996. The TLDs were exchanged and analyzed quarterly. All routine area monitoring TLD results were less than 50 mrem annually after correcting for worker occupancy. The results support the conclusion that personnel dosimeters are not necessary for staff, declared pregnant workers, minors, or members of the public in these monitoredmore »
- Authors:
- Publication Date:
- Research Org.:
- Pacific Northwest National Lab. (PNNL), Richland, WA (United States)
- Sponsoring Org.:
- USDOE Assistant Secretary for Environment, Safety, and Health, Washington, DC (United States)
- OSTI Identifier:
- 527483
- Report Number(s):
- PNNL-11594
ON: DE97053373; TRN: AHC29720%%75
- DOE Contract Number:
- AC06-76RL01830
- Resource Type:
- Technical Report
- Resource Relation:
- Other Information: PBD: Jun 1997
- Country of Publication:
- United States
- Language:
- English
- Subject:
- 56 BIOLOGY AND MEDICINE, APPLIED STUDIES; BATTELLE PACIFIC NORTHWEST LABORATORIES; PERSONNEL MONITORING; RADIATION PROTECTION; NUMERICAL DATA; THERMOLUMINESCENT DOSIMETRY; RADIATION DOSES
Citation Formats
Bivins, S R, and Stoetzel, G A. Area monitoring dosimeter program for the Pacific Northwest National Laboratory: Results for CY 1996. United States: N. p., 1997.
Web. doi:10.2172/527483.
Bivins, S R, & Stoetzel, G A. Area monitoring dosimeter program for the Pacific Northwest National Laboratory: Results for CY 1996. United States. https://doi.org/10.2172/527483
Bivins, S R, and Stoetzel, G A. 1997.
"Area monitoring dosimeter program for the Pacific Northwest National Laboratory: Results for CY 1996". United States. https://doi.org/10.2172/527483. https://www.osti.gov/servlets/purl/527483.
@article{osti_527483,
title = {Area monitoring dosimeter program for the Pacific Northwest National Laboratory: Results for CY 1996},
author = {Bivins, S R and Stoetzel, G A},
abstractNote = {In January 1993, Pacific Northwest National Laboratory (PNNL) established an area monitoring dosimeter program in accordance with Article 514 of the Department of Energy (DOE) Radiological Control Manual (RCM). The purpose of the program was to minimize the number of areas requiring issuance of personnel dosimeters and to demonstrate that doses outside Radiological buffer Areas are negligible. In accordance with 10 CFR Part 835.402 (a) (1)-(3) and Article 511.1 of the RCM, personnel dosimetry shall be provided to (1) radiological workers who are likely to receive at least 100 mrem annually and (2) declared pregnant workers, minors, and members of the public who are likely to receive at least 50 mrem annually. Program results for calendar years 1993, 1994, and 1995 confirmed that personnel dosimetry was not needed for individuals located in areas monitored by the program. A total of 108 area TLDs were placed in PNNL facilities during CY 1996. The TLDs were exchanged and analyzed quarterly. All routine area monitoring TLD results were less than 50 mrem annually after correcting for worker occupancy. The results support the conclusion that personnel dosimeters are not necessary for staff, declared pregnant workers, minors, or members of the public in these monitored areas.},
doi = {10.2172/527483},
url = {https://www.osti.gov/biblio/527483},
journal = {},
number = ,
volume = ,
place = {United States},
year = {Sun Jun 01 00:00:00 EDT 1997},
month = {Sun Jun 01 00:00:00 EDT 1997}
}