Improved performance of the ATA injector
Conference
·
OSTI ID:5270920
During the last year we re-configured the ATA injector to accommodate field emission cathodes. The injector is now run as a diode machine with a 7 cm radius cathode, an A-K gap of 12.9 cm and a field stress of 190 kV/cm. The advantage of using field emission cathodes is we have increased the injector brightness by a factor of ten above the level we were able to reach using the low density plasma cathodes.